EVALUATION OF RADIOSURGERY TECHNIQUES WITH CUMULATIVE DOSE VOLUME HISTOGRAMS IN LINAC-BASED STEREOTAXIC EXTERNAL BEAM IRRADIATION

被引:27
作者
SCHELL, MC
SMITH, V
LARSON, DA
WU, A
FLICKINGER, JC
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIAT ONCOL,SAN FRANCISCO,CA 94143
[2] UNIV PITTSBURGH,PITTSBURGH,PA 15260
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1991年 / 20卷 / 06期
关键词
DOSE VOLUME HISTOGRAMS; TREATMENT PLANNING; STEREOTAXIC EXTERNAL BEAM IRRADIATION; RADIOSURGERY;
D O I
10.1016/0360-3016(91)90245-Y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiosurgery at UCSF is performed with a 6-MV linear accelerator with tertiary collimation for improved small field definition. The dose delivery to the target relative to normal tissue is influenced by the number of arcs, the arc geometry, field size, and beam energy. The impact of arc number, arc geometry, and field size on the dose distribution from 6-MV X rays in a 16 cm spherical phantom has been evaluated through the use of cumulative dose volume histograms. Dose volume histograms were calculated for a) 1-5 and 10 arcs, and b) collimator sizes of 1.25, 2.0, and 3.0 cm. Differences between techniques were found at the 5-10% level for field sizes from 1.25 to 2.0 cm. It was shown that the finite dimension of the sphere and, by extension, head diminishes the differences between techniques for the larger field sizes. The effect of treating with two isocenters is also analyzed and an approach for improving the dose distribution is presented.
引用
收藏
页码:1325 / 1330
页数:6
相关论文
共 19 条
[1]   DOSE VOLUME HISTOGRAMS IN TREATMENT PLANNING [J].
CHEN, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06) :1319-1320
[2]   DOSIMETRIC CONSIDERATIONS ON MULTIPLE ARC STEREOTAXIC RADIOTHERAPY [J].
CHIEREGO, G ;
MARCHETTI, C ;
AVANZO, RC ;
POZZA, F ;
COLOMBO, F .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :141-152
[3]   EXTERNAL STEREOTACTIC IRRADIATION BY LINEAR-ACCELERATOR [J].
COLOMBO, F ;
BENEDETTI, A ;
POZZA, F ;
AVANZO, RC ;
MARCHETTI, C ;
CHIEREGO, G ;
ZANARDO, A .
NEUROSURGERY, 1985, 16 (02) :154-160
[4]   STEREOTACTIC HEAVY-ION BRAGG PEAK RADIOSURGERY FOR INTRA-CRANIAL VASCULAR DISORDERS - METHOD FOR TREATMENT OF DEEP ARTERIOVENOUS-MALFORMATIONS [J].
FABRIKANT, JI ;
LYMAN, JT ;
HOSOBUCHI, Y .
BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (678) :479-490
[5]   AN INTEGRATED LOGISTIC FORMULA FOR PREDICTION OF COMPLICATIONS FROM RADIOSURGERY [J].
FLICKINGER, JC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (04) :879-885
[6]   CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY [J].
HARTMANN, GH ;
SCHLEGEL, W ;
STURM, V ;
KOBER, B ;
PASTYR, O ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06) :1185-1192
[7]  
KJELLBERG RN, 1986, ANN CLIN RES, V47, P17
[8]  
LEKSELL L, 1951, ACTA CHIR SCAND, V102, P316
[9]  
LUNSFORD LD, 1987, APPL NEUROPHYSIOL, V50, P253
[10]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381