EVALUATION OF RADIOSURGERY TECHNIQUES WITH CUMULATIVE DOSE VOLUME HISTOGRAMS IN LINAC-BASED STEREOTAXIC EXTERNAL BEAM IRRADIATION

被引:27
作者
SCHELL, MC
SMITH, V
LARSON, DA
WU, A
FLICKINGER, JC
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIAT ONCOL,SAN FRANCISCO,CA 94143
[2] UNIV PITTSBURGH,PITTSBURGH,PA 15260
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1991年 / 20卷 / 06期
关键词
DOSE VOLUME HISTOGRAMS; TREATMENT PLANNING; STEREOTAXIC EXTERNAL BEAM IRRADIATION; RADIOSURGERY;
D O I
10.1016/0360-3016(91)90245-Y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiosurgery at UCSF is performed with a 6-MV linear accelerator with tertiary collimation for improved small field definition. The dose delivery to the target relative to normal tissue is influenced by the number of arcs, the arc geometry, field size, and beam energy. The impact of arc number, arc geometry, and field size on the dose distribution from 6-MV X rays in a 16 cm spherical phantom has been evaluated through the use of cumulative dose volume histograms. Dose volume histograms were calculated for a) 1-5 and 10 arcs, and b) collimator sizes of 1.25, 2.0, and 3.0 cm. Differences between techniques were found at the 5-10% level for field sizes from 1.25 to 2.0 cm. It was shown that the finite dimension of the sphere and, by extension, head diminishes the differences between techniques for the larger field sizes. The effect of treating with two isocenters is also analyzed and an approach for improving the dose distribution is presented.
引用
收藏
页码:1325 / 1330
页数:6
相关论文
共 19 条
[11]   COMPARISON OF DIFFERENT RADIATION TYPES AND IRRADIATION GEOMETRIES IN STEREOTACTIC RADIOSURGERY [J].
PHILLIPS, MH ;
FRANKEL, KA ;
LYMAN, JT ;
FABRIKANT, JI ;
LEVY, RP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :211-220
[12]  
PIKE B, 1987, APPL NEUROPHYSIOL, V50, P269
[13]   DYNAMIC STEREOTACTIC RADIOSURGERY [J].
PODGORSAK, EB ;
OLIVIER, A ;
PLA, M ;
LEFEBVRE, PY ;
HAZEL, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (01) :115-126
[14]   RADIOSURGERY WITH HIGH-ENERGY PHOTON BEAMS - A COMPARISON AMONG TECHNIQUES [J].
PODGORSAK, EB ;
PIKE, GB ;
OLIVIER, A ;
PLA, M ;
SOUHAMI, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (03) :857-865
[15]   MEASUREMENTS OF DOSE DISTRIBUTIONS IN SMALL BEAMS OF 6 MV X-RAYS [J].
RICE, RK ;
HANSEN, JL ;
SVENSSON, GK ;
SIDDON, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1087-1099
[16]   STEREOTAXIC LOCALIZATION OF INTRACRANIAL TARGETS [J].
SIDDON, RL ;
BARTH, NH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08) :1241-1246
[17]  
SMITH V, 1989, MED PHYS, V16, P461
[18]  
STEINER L, 1984, INTRACRANIAL ARTERIO, P295
[19]   A CT-BASED COMPUTERIZED TREATMENT PLANNING SYSTEM FOR I-125 STEREOTACTIC BRAIN IMPLANTS [J].
WEAVER, K ;
SMITH, V ;
LEWIS, JD ;
LULU, B ;
BARNETT, CM ;
LEIBEL, SA ;
GUTIN, P ;
LARSON, D ;
PHILLIPS, T .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (02) :445-454