ON-AXIS AND OFF-AXIS PRIMARY DOSE COMPONENT IN HIGH-ENERGY PHOTON BEAMS

被引:42
作者
ZEFKILI, S [1 ]
KAPPAS, C [1 ]
ROSENWALD, JC [1 ]
机构
[1] UNIV PATRAS,FAC MED,DEPT MED PHYS,GR-26500 PATRAI,GREECE
关键词
PHOTON BEAM QUALITY; FLATTENING FILTER; ENERGY SPECTRA; LINEAR ACCELERATOR;
D O I
10.1118/1.597325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The depth dose of the primary dose component, on axis and off axis of six different x-ray beams, has been determined from transmission measurements in narrow beam geometry with and without flattening filter using a Perspex column of a cross section large enough to ensure electronic equilibrium. In order to derive the primary photon fluence, a correction for the scatter from the column has been applied according to the following method: A number of spectra taken from the literature have been used for computing a scatter coefficient S(c) at different depths by convolution of dose spread arrays. Using the relationship between S(c) and the single attenuation coefficient mu(i) to represent each entire spectrum, it has been possible to correct the experimental transmission curves iteratively, until the corresponding values of mu were stabilized and representative of the primary. The measured attenuation coefficients were found to have a linear increase as a function of the distance from the central axis for all the energies and types of linear accelerators. For the same nominal energy, this increase is different from one accelerator to another. The same phenomenon was observed for the attenuation coefficients obtained without the flattening filter in the same experimental conditions. The results are tentatively interpreted considering the angular variation of bremsstrahlung energy spectra with and without a flattening filter as calculated by a Monte Carlo method and they are consistent and useful to take accurately into account the softening of the beam as the off-axis distance increases.
引用
收藏
页码:799 / 808
页数:10
相关论文
共 23 条
[1]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[2]  
[Anonymous], 1983, MED PHYS, V10, P741
[3]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[4]   METHOD FOR CALCULATION OF DOSE IN RADIATION TREATMENT OF HODGKINS-DISEASE [J].
CUNDIFF, JH ;
CUNNINGHAM, JR ;
GOLDEN, R ;
LANZL, HL ;
MEURK, ML ;
OVADIA, J ;
LAST, VP ;
POPE, RA ;
SAMPIERE, VA ;
SAYLOR, WL ;
SUNTHARALINGHAM, N ;
SHALEK, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1973, 117 (01) :30-44
[5]   OFF-AXIS BEAM QUALITY CHANGE IN LINEAR-ACCELERATOR X-RAY-BEAMS [J].
HANSON, WF ;
BERKLEY, LW ;
PETERSON, M .
MEDICAL PHYSICS, 1980, 7 (02) :145-146
[6]   CALCULATIVE TECHNIQUE TO CORRECT FOR THE CHANGE IN LINEAR-ACCELERATOR BEAM ENERGY AT OFF-AXIS POINTS [J].
HANSON, WF ;
BERKLEY, LW ;
PETERSON, M .
MEDICAL PHYSICS, 1980, 7 (02) :147-150
[7]  
Jenkins TM., 1988, MONTE CARLO TRANSPOR
[8]   ANALYTIC REPRESENTATION OF THE BACKSCATTER CORRECTION FACTOR AT THE EXIT OF HIGH-ENERGY PHOTON BEAMS [J].
KAPPAS, K ;
ROSENWALD, JC .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (02) :128-134
[9]  
KAPPAS K, 1986, THESIS U P SABATIER
[10]  
KEPTA A, 1985, PHYS MED BIOL, V30, P589