Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray

被引:12
作者
Adams, EJ
Hounsell, AR
机构
[1] North Western Medical Physics Department, Christie Hospital, Holt Radium Institute, Manchester
关键词
build-up dose; lead blocking; multi-leaf collimators;
D O I
10.1016/0167-8140(95)01662-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Doses in the build-up region have been compared for regular fields with and without a perspex accessory tray and for two irregular fields defined by either a Philips multi-leaf collimator (MLC) or lead blocks. The results show an increase in doses within the build-up region, by up to a factor of two, primarily due to the presence of the accessory tray. Fields shaped with the MLC exhibited build-up characteristics similar to those in unblocked fields and hence there will be systematic changes to the build-up dose when treatments are transferred from lead blocking techniques to those using an MLC mounted within the treatment head.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 10 条
[1]  
[Anonymous], 1983, MED PHYS, V10, P741
[2]   SECONDARY-ELECTRON SCATTER IN RADIOTHERAPY - IMPLICATIONS FOR TREATMENT FIELDS IN PROXIMITY TO THE LENS OF THE EYE AND THE TESTES [J].
BECKHAM, WA .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (07) :1013-1018
[3]   EFFECTS OF BEAM MODIFIERS AND IMMOBILIZATION DEVICES ON THE DOSE IN THE BUILDUP REGION [J].
FONTENLA, DP ;
NAPOLI, JJ ;
HUNT, M ;
FASS, D ;
MCCORMICK, B ;
KUTCHER, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (01) :211-219
[4]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192
[5]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[6]   THE POLARITY EFFECT FOR COMMERCIALLY AVAILABLE PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1987, 14 (02) :210-215
[7]   THE DESIGN AND PERFORMANCE-CHARACTERISTICS OF A MULTILEAF COLLIMATOR [J].
JORDAN, TJ ;
WILLIAMS, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :231-251
[8]   DETERMINATION OF BUILDUP REGION OVER-RESPONSE CORRECTIONS FOR A MARKUS-TYPE CHAMBER [J].
MELLENBERG, DE .
MEDICAL PHYSICS, 1990, 17 (06) :1041-1044
[9]   INVESTIGATIONS ON THE NEAR-SURFACE DOSE FOR 3 10-MV X-RAY-BEAM ACCELERATORS WITH EMPHASIS ON THE REDUCTION OF ELECTRON CONTAMINATION [J].
RAO, BM ;
PRASAD, SG ;
PARTHASARADHI, K ;
LEE, Y ;
RUPAREL, R ;
GARCES, R .
MEDICAL PHYSICS, 1988, 15 (02) :246-249
[10]  
WEBB S, 1993, PHYSICS 3 DIMENSIONA