THRESHOLD SELECTION FOR CT ANGIOGRAPHY SHADED SURFACE DISPLAY OF THE RENAL-ARTERIES

被引:23
作者
HALPERN, EJ
WECHSLER, RJ
DICAMPLI, D
机构
[1] Department of Radiology, Jefferson Medical College, Thomas Jefferson University Hospital, Philadelphia, 19107-5244, PA
关键词
D O I
10.1007/BF03168088
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to define objective criteria to calculate a tissue segmentation threshold for shaded surface display (SSD) rendering of the renal arteries with computed tomography angiography. Contrast-enhanced spiral CT scans were obtained through the renal arteries of nine patients. Six sets of SSD images were rendered for each patient with lower threshold values ranging from 80 to 130 Hounsfield units (HU) by increments of 10 HU. Visceral organ enhancement was measured in the aorta, liver, spleen, pancreas, and kidney. The segmentation threshold for each patient was determined by evaluation of the SSD images alone as well as by comparison with conventional arteriograms. The ideal threshold, as shown by comparison with conventional arteriography, was better correlated with a threshold value selected by qualitative evaluation of SSD images alone (r(s) = .42), than with measured enhancement in visceral organs (r(s) = -.289 to .009). The degree of stenosis was overestimated in a single renal artery (1 of 18) because of an inappropriate threshold selected by evaluation of the SSD images alone. In comparison with a segmentation threshold calculated from measured enhancement of visceral organs, a segmentation threshold selected by qualitative evaluation of the resulting SSD images is more likely to approximate the ideal threshold. Given the subjective nature of such threshold selection, further evaluation is warranted to determine whether threshold selection may result in inaccurate grading of stenosis. (C) 1995 W.B. Saunders Company
引用
收藏
页码:142 / 147
页数:6
相关论文
共 12 条
  • [1] TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS
    BRINK, JA
    LIM, JT
    WANG, G
    HEIKEN, JP
    DEYOE, LA
    VANNIER, MW
    [J]. RADIOLOGY, 1995, 194 (01) : 157 - 163
  • [2] FARRELL EJ, 1989, CRIT REV BIOMED ENG, V16, P323
  • [3] 3-DIMENSIONAL IMAGING
    FISHMAN, EK
    MAGID, D
    NEY, DR
    CHANEY, EL
    PIZER, SM
    ROSENMAN, JG
    LEVIN, DN
    VANNIER, MW
    KUHLMAN, JE
    ROBERTSON, DD
    [J]. RADIOLOGY, 1991, 181 (02) : 321 - 337
  • [4] RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY
    GALANSKI, M
    PROKOP, M
    CHAVAN, A
    SCHAEFER, CM
    JANDELEIT, K
    NISCHELSKY, JE
    [J]. RADIOLOGY, 1993, 189 (01) : 185 - 192
  • [5] EVALUATION OF METHODS FOR SHADED SURFACE DISPLAY OF CT VOLUMES
    MAGNUSSON, M
    LENZ, R
    DANIELSSON, PE
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1991, 15 (04) : 247 - 256
  • [6] MENDENHALL W, 1973, MATH STATISTICS APPL, P548
  • [7] CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION
    NAPEL, S
    MARKS, MP
    RUBIN, GD
    DAKE, MD
    MCDONNELL, CH
    SONG, SM
    ENZMANN, DR
    JEFFREY, RB
    [J]. RADIOLOGY, 1992, 185 (02) : 607 - 610
  • [8] Ney D R, 1992, J Digit Imaging, V5, P242
  • [9] 3-DIMENSIONAL SPIRAL COMPUTED TOMOGRAPHIC ANGIOGRAPHY - AN ALTERNATIVE IMAGING MODALITY FOR THE ABDOMINAL-AORTA AND ITS BRANCHES
    RUBIN, GD
    WALKER, PJ
    DAKE, MD
    NAPEL, S
    JEFFREY, RB
    MCDONNELL, CH
    MITCHELL, RS
    MILLER, DC
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (04) : 656 - 665
  • [10] 3-DIMENSIONAL SPIRAL CT ANGIOGRAPHY OF THE ABDOMEN - INITIAL CLINICAL-EXPERIENCE
    RUBIN, GD
    DAKE, MD
    NAPEL, SA
    MCDONNELL, CH
    JEFFREY, RB
    [J]. RADIOLOGY, 1993, 186 (01) : 147 - 152