FAST AMPEROMETRIC IMMUNOASSAY UTILIZING HIGHLY DISPERSED ELECTRODE MATERIAL

被引:28
作者
KRISHNAN, R
GHINDILIS, AL
ATANASOV, P
WILKINS, E
机构
[1] Department of Chemical and Nuclear Engineering, university of New Mexico, Albuquerque, New Mexico
关键词
AMPEROMETRIC IMMUNOASSAY; IMMUNOELECTRODE; IMMUNOSENSOR;
D O I
10.1080/00032719508004028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunoassay technique based on a high surface area carbon immunoelectrode is described. Dispersed ULTI carbon serves as a carrier for immobilized antibodies and also as an electrode material. 'Sandwich' scheme of immunoassay of rabbit IgG (as a model analyte) has been used. Iodine formed as a result of the enzymatic oxidation of iodide by peroxidase-label has been detected amperometrically. Using dispersed carbon material as a solid support for immobilization of immunoagents and as an electrode material improves the efficiency of immune-interaction and the sensitivity of electrochemical assay due to the high area-to-volume ratio of solid to liquid phases. The method based on 'sandwich' immunoassay is conducted at 21 degrees C. The time of each stage of incubation (with analyte and with peroxidase-antibody conjugate) is 10 min. Electrochemical detection of peroxidase-labeled immuno-complex does not exceed several minutes. The technique allows fast determination of rabbit IgG with a low detection limit, in the nanomolar range. By comparison, the conventional technique based on ELISA, being performed under the same conditions (temperature and incubation time) does not allow any quantitative determination of IgG for concentration lower then 100 nM.
引用
收藏
页码:2459 / 2474
页数:16
相关论文
共 16 条
  • [1] A NEW VISUAL ENZYME-IMMUNOASSAY OF METHAMPHETAMINE USING LINEAR WATER-SOLUBLE POLYELECTROLYTES
    DZANTIEV, BB
    CHOI, MJ
    PARK, J
    CHOI, J
    ROMANENKO, OG
    ZHERDEV, AV
    EREMIN, SA
    IZUMRUDOV, VA
    [J]. IMMUNOLOGY LETTERS, 1994, 41 (2-3) : 205 - 211
  • [2] MEASUREMENT OF ALKALINE-PHOSPHATASE ACTIVITY BY ELECTROCHEMICAL DETECTION OF PHOSPHATE-ESTERS - APPLICATION TO AMPEROMETRIC ENZYME-IMMUNOASSAY
    FREW, JE
    FOULDS, NC
    WILSHERE, JM
    FORROW, NJ
    GREEN, MJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (02): : 309 - 316
  • [3] DETERMINATION OF P-AMINOPHENOL AND CATECHOLAMINES AT PICOMOLAR CONCENTRATIONS BASED ON RECYCLING ENZYME AMPLIFICATION
    GHINDILIS, AL
    MAKOWER, A
    BAUER, CG
    BIER, FF
    SCHELLER, FW
    [J]. ANALYTICA CHIMICA ACTA, 1995, 304 (01) : 25 - 31
  • [4] GHINDILIS AL, 1995, ANAL LETT, V28, P1
  • [5] SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS
    HAYES, FJ
    HALSALL, HB
    HEINEMAN, WR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (11) : 1860 - 1865
  • [6] FLOW-INJECTION AMPEROMETRIC SYSTEM FOR ENZYME-IMMUNOASSAY
    IVNITSKII, DM
    SITDIKOV, RA
    KUROCHKIN, VE
    [J]. ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 45 - 52
  • [7] ELECTROCHEMICAL ENZYME-IMMUNOASSAY USING SEQUENTIAL SATURATION TECHNIQUE IN A 20-MUL CAPILLARY - DIGOXIN AS A MODEL ANALYTE
    KANEKI, N
    XU, Y
    KUMARI, A
    HALSALL, HB
    HEINEMAN, WR
    KISSINGER, PT
    [J]. ANALYTICA CHIMICA ACTA, 1994, 287 (03) : 253 - 258
  • [8] A CONTINUOUS-FLOW IMMUNOASSAY FOR RAPID AND SENSITIVE DETECTION OF SMALL MOLECULES
    KUSTERBECK, AW
    WEMHOFF, GA
    CHARLES, PT
    YEAGER, DA
    BREDEHORST, R
    VOGEL, CW
    LIGLER, FS
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 135 (1-2) : 191 - 197
  • [9] UTILIZATION OF A NAFION(R)-MODIFIED ELECTRODE IN A COMPETITIVE HOMOGENEOUS ELECTROCHEMICAL IMMUNOASSAY INVOLVING A REDOX CATIONIC LABELED HAPTEN PHENYTOIN
    LASALLE, AL
    LIMOGES, B
    ANIZON, JY
    DEGRAND, C
    BROSSIER, P
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 350 (1-2): : 329 - 335
  • [10] HOMOGENEOUS ELECTROCHEMICAL IMMUNOASSAY USING A PERFLUOROSULFONATED IONOMER-MODIFIED ELECTRODE AS DETECTOR FOR A CATIONIC-LABELED HAPTEN
    LIMOGES, B
    DEGRAND, C
    BROSSIER, P
    BLANKESPOOR, RL
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (08) : 1054 - 1060