APPLICATION OF ATR-IR TO THE ANALYSIS OF SURFACE-STRUCTURE AND ORIENTATION IN UNIAXIALLY DRAWN POLY(ETHYLENETEREPHTHALATE)

被引:66
作者
WALLS, DJ
机构
关键词
INFRARED; ATR; POLY(ETHYLENETEREPHTHALATE); PET;
D O I
10.1366/0003702914336147
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A critical examination of the use of ATR-IR for the examination of surface composition and orientation in uniaxially drawn poly(ethyleneterephthalate) (PET) films has been performed. This work has identified the band at 1410 cm-1 as a satisfactory reference band in ATR-IR analyses for surface composition and orientation analyses in oriented PET films. Other commonly used reference bands at 790 and 1510 cm-1 have been shown to be influenced by both incident infrared polarization and orientation within the polymer films. Control of sample clamping pressure in a conventional ATR-IR clamp has been shown to afford optimized sample contact, needed in conjunction with the use of valid reference bands to obtain reproducible in-plane surface dichroism measurements of films with varying degrees of orientation.
引用
收藏
页码:1193 / 1198
页数:6
相关论文
共 25 条
[22]  
WALLS DF, UNPUB
[23]   IR AND RAMAN-SPECTRA OF POLY(M-METHYLENE TEREPHTHALATE) POLYMERS [J].
WARD, IM ;
WILDING, MA .
POLYMER, 1977, 18 (04) :327-335
[24]  
Zbinden R., 1964, INFRARED SPECTROSCOP
[25]  
[No title captured]