SYNTHESIS AND POTENTIOMETRIC STUDY OF ACYCLIC MONOXADIAMIDES AS IONOPHORES IN ION-SELECTIVE ELECTRODES

被引:17
作者
ATTIYAT, AS
KADRY, AM
BADAWY, MA
HANNA, HR
IBRAHIM, YA
CHRISTIAN, GD
机构
[1] UNIV WASHINGTON,DEPT CHEM,BG-10,SEATTLE,WA 98195
[2] YARMOUK UNIV,DEPT CHEM,IRBID,JORDAN
[3] ZAGAZIG UNIV,FAC PHARM,DEPT ENVIRONM HYG,ZAGAZIG,EGYPT
[4] UNIV CAIRO,FAC SCI,DEPT CHEM,GIZA,EGYPT
关键词
D O I
10.1002/elan.1140020207
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Seven compounds of a new class of ionophores, acyclic monoxadiamides, were synthesized and tested for the potentiometric selectivity for lithium ion, in polyvinyl chloride (PVC) membrane electrodes. Four different plasticizers were studied: o‐nitrophenyloctyl ether (NPOE), o‐nitrophenylphenyl ether (NPPE), o‐nitrophenylbutyl ether (NPBE), and o‐nitrophenylbenzyl ether (NPBnE), as was the addition of trioctylphosphine oxide (TOPO). The ionophore o‐carboxyphenoxyacetic acid dimorpholide (Ig) exhibited sodium‐lithium selectivity, K Li, Napot, of 0.018 by the matched‐potential method in the presence of 1% TOPO using NPBE plasticizer. The presence of TOPO generally causes a substantial increase in the lithium selectivity, but it decreases the slopes of the calibration curves. Selectivities are reported for sodium, potassium, ammonium, barium, and calcium ions with respect to the lithium ion. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 45 条
[11]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[12]   COATED-WIRE LITHIUM ION-SELECTIVE ELECTRODES BASED ON POLYALKOXYLATE COMPLEXES [J].
GADZEKPO, VPY ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1985, 110 (11) :1381-1385
[13]   1,4,7,10-TETRAOXACYCLODODECANE(12-CROWN-4) AS NEUTRAL CARRIER FOR LITHIUM ION IN LITHIUM ION-SELECTIVE ELECTRODE [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1983, 16 (17-1) :1371-1380
[14]  
GADZEKPO VPY, 1986, ION SEL ELECTRODE R, V8, P173
[15]   COMPARATIVE-STUDY OF NEUTRAL CARRIERS IN POLYMERIC LITHIUM ION-SELECTIVE ELECTRODES [J].
GADZEKPO, VPY ;
HUNGERFORD, JM ;
KADRY, AM ;
IBRAHIM, YA ;
XIE, RY ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1986, 58 (09) :1948-1953
[16]   PROBLEMS IN THE APPLICATION OF ION-SELECTIVE ELECTRODES TO SERUM LITHIUM ANALYSIS [J].
GADZEKPO, VPY ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1986, 111 (05) :567-570
[17]  
GADZEKPO VPY, 1984, THESIS U WASHINGTON
[18]  
GADZEKPO VPY, UNPUB
[19]  
GUGGI M, 1975, ANAL LETT, V8, P857
[20]  
GUGGI M, 1977, THESIS SWISS FEDERAL