A QUARTZ-CRYSTAL MICROBALANCE STUDY OF THE CORROSION OF IRON THIN-FILMS IN NEUTRAL AQUEOUS-SOLUTIONS

被引:17
作者
SEO, M
YOSHIDA, K
NODA, K
机构
[1] Faculty of Engineering, Hokkaido University, Kita-ku, Sapporo, 060, Kita-13 Jo
来源
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING | 1995年 / 198卷 / 1-2期
关键词
QUARTZ CRYSTAL MICROBALANCE; IRON THIN FILM; CORROSION RATE; CORROSION MECHANISM; NEUTRAL AQUEOUS SOLUTION;
D O I
10.1016/0921-5093(95)80074-5
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The quartz crystal microbalance (QCM) technique is capable of detecting small mass changes in the region of nanograms per square centimetre from resonant frequency changes of the quartz crystal. In this study, the QCM technique, combined with electrochemical measurements, was applied to the minute corrosion of iron thin films in deaerated neutral solutions. An iron thin film with a thickness of 200 nm was electroplated on the gold electrode of a quartz crystal. The mass changes of the iron thin film during natural immersion or galvanostatic polarization in deaerated pH 6.48 berate solution, pH 6.42 berate solution with 10(-2) M chloride ions, pH 6.0 berate solution with 0.5 M chloride ions and pH 6.48 phosphate solution were measured as a function of time or potential to evaluate the iron dissolution rate or iron dissolution current. The corrosion rate of the iron thin film on natural immersion increased in the order pH 6.48 phosphate > pH 6.0 berate with 0.5 M chloride ions > pH 6.42 berate with 10(-2) M chloride ions > pH 6.48 berate solution. The net current flowing through the external circuit during galvanostatic polarization near the corrosion potential was successfully separated into the iron dissolution current and hydrogen evolution current. Tafel plots of the iron dissolution current and hydrogen evolution current were made to evaluate the corrosion mechanism of the iron thin film. The Tafel slopes of iron dissolution and hydrogen evolution thus obtained depend on the electrolyte solutions, from which conclusions can be drawn on the corrosion mechanism.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 29 条
[1]  
Bockris J. O. M., 1961, ELECTROCHIM ACTA, V4, P325, DOI DOI 10.1016/0013-4686(61)80026-1
[2]   EXPERIMENTAL ASPECTS OF USE OF THE QUARTZ CRYSTAL MICROBALANCE IN SOLUTION [J].
BRUCKENSTEIN, S ;
SHAY, M .
ELECTROCHIMICA ACTA, 1985, 30 (10) :1295-1300
[3]   INFLUENCE OF CHLORIDE-IONS ON KINETICS OF IRON DISSOLUTION [J].
DARWISH, NA ;
HILBERT, F ;
LORENZ, WJ ;
ROSSWAG, H .
ELECTROCHIMICA ACTA, 1973, 18 (06) :421-425
[4]  
DRAZIC DM, 1989, MOD ASPECT ELECTROC, V19, P120
[5]   ROLE OF CHLORIDE ION IN IRON CORROSION [J].
FOLEY, RT .
CORROSION, 1970, 26 (02) :58-&
[6]  
FREIMAN LI, 1965, ZASHCH MET, V1, P161
[7]   INSITU GRAVIMETRY OF PASSIVATION OF COPPER BY MEANS OF QUARTZ CRYSTAL MICROBALANCE [J].
GRASJO, L ;
SEO, M ;
SATO, N .
CORROSION SCIENCE, 1990, 31 :299-304
[8]   MEASUREMENT OF ABSORPTION OF HYDROGEN AND DEUTERIUM INTO PALLADIUM DURING ELECTROLYSIS BY A QUARTZ CRYSTAL MICROBALANCE [J].
GRASJO, L ;
SEO, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 296 (01) :233-239
[9]  
GRZEGORZEWSKI A, 1987, J ELECTROANAL CHEM, V28, P455
[10]  
Heusler K. E, 1982, ENCY ELECTROCHEMIS A, VIX, P311