POLYURETHANE OR SILICONE AS A MATERIAL FOR LONG-TERM IMPLANTS - A CRITICAL-REVIEW

被引:10
作者
BEHREND, D
SCHMITZ, KP
机构
来源
BIOMEDIZINISCHE TECHNIK | 1993年 / 38卷 / 7-8期
关键词
BIO-DEGRADADITION; SILICONE; POLYURETHANE; IN-VIVO;
D O I
10.1515/bmte.1993.38.7-8.172
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Long-term implants made from thermoplastic elastomers have a long history of clinical use. Among other rubber materials, such as polyolefin rubber, much of the demand for rubber-like biomaterials is met by silicone and polyurethane elastomers. The last two elastomers both have sufficient biocompatibility for long-term applications, but differ in terms of biodegradability. Inadequate resistance to degradation almost always leads to implant function loss, which may even threaten the patient's life. Long-term implantation studies in the rat show different mechanisms of biodegradation for polyurethane and silicone. Polyurethane shown deep fissures in the surface, compared with erosion of silicone surfaces. Mechanical and electrical parameters determined to evaluate degradation, additionally show differences in the extent of damage occurring.
引用
收藏
页码:172 / 178
页数:7
相关论文
共 56 条
[21]   EFFECTS OF IMPLANTATION ON THE MECHANICAL-PROPERTIES OF THE POLYURETHANE DIAPHRAGM OF LEFT-VENTRICULAR ASSIST DEVICES [J].
HAYASHI, K ;
MATSUDA, T ;
TAKANO, H ;
UMEZU, M ;
TAENAKA, Y ;
NAKAMURA, T .
BIOMATERIALS, 1985, 6 (02) :82-88
[22]  
HAYASHI K, 1985, Journal of Biomedical Materials Research, V19, P133, DOI 10.1002/jbm.820190204
[23]   MECHANICAL STABILITY OF ELASTOMERIC POLYMERS FOR BLOOD PUMP APPLICATIONS [J].
HAYASHI, K ;
TAKANO, H ;
MATSUDA, T ;
UMEZU, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (02) :179-193
[24]   A MULTICENTER EXPERIENCE WITH A BIPOLAR TINED POLYURETHANE VENTRICULAR LEAD [J].
HAYES, DL ;
GRAHAM, KJ ;
IRWIN, M ;
VIDAILLET, H ;
DISLER, G ;
SWEESY, M ;
OSBORN, MJ ;
SUMAN, VJ ;
NEUBAUER, SA ;
SEEBANDT, M ;
KALLINEN, L ;
CROWSON, CS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07) :1033-1039
[25]  
HEPPERLE W, 1981, SYSPUR REPORTER, V19, P219
[26]   INVIVO FRAGMENTATION OF MICROPOROUS POLYURETHANE-BASED AND COPOLYESTERETHER ELASTOMER-BASED VASCULAR PROSTHESES [J].
HINRICHS, WLJ ;
KUIT, J ;
FEIL, H ;
WILDEVUUR, CRH ;
FEIJEN, J .
BIOMATERIALS, 1992, 13 (09) :585-593
[27]   CELLULAR REACTION TO THE VASCUGRAFT - POLYESTERURETHANE VASCULAR PROSTHESIS - INVIVO STUDIES IN RATS [J].
HUANG, B ;
MAROIS, Y ;
ROY, R ;
JULIEN, M ;
GUIDOIN, R .
BIOMATERIALS, 1992, 13 (04) :209-216
[28]  
HUNTER SK, 1983, T AM SOC ART INT ORG, V29, P250
[29]  
IVES CL, 1984, T ASAIO, V30, P5875
[30]   MODIFICATION OF POLYETHERURETHANE FOR BIOMEDICAL APPLICATION BY RADIATION-INDUCED GRAFTING .2. WATER SORPTION, SURFACE-PROPERTIES, AND PROTEIN ADSORPTION OF GRAFTED FILMS [J].
JANSEN, B ;
ELLINGHORST, G .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (06) :655-669