DYNAMICS OF TUMOR IMAGING WITH GD-DTPA POLYETHYLENE-GLYCOL POLYMERS - DEPENDENCE ON MOLECULAR-WEIGHT

被引:75
作者
DESSER, TS [1 ]
RUBIN, DL [1 ]
MULLER, HH [1 ]
QING, F [1 ]
KHODOR, S [1 ]
ZANAZZI, G [1 ]
YOUNG, SW [1 ]
LADD, DL [1 ]
WELLONS, JA [1 ]
KELLAR, KE [1 ]
TONER, JL [1 ]
SNOW, RA [1 ]
机构
[1] STERLING WINTHROP INC,STERLING WINTHROP PHARMACEUT RES DIV,COLLEGEVILLE,PA
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 03期
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; BLOOD POOL; EXPERIMENTAL STUDIES; GADOLINIUM; NEOPLASMS;
D O I
10.1002/jmri.1880040337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Macromolecular contrast media offer potential advantages over freely diffusible agents in magnetic resonance (MR) imaging outside the central nervous system. To identify an optimum molecular weight for macromolecular contrast media, the authors studied a novel macromolecular contrast agent, gadolinium diethylenetriaminepentaacetic acid polyethylene glycol (DTPA-PEG), synthesized in seven polymer (average) molecular weights ranging from 10 to 83 kd. Twenty-eight rabbits bearing V2 carcinoma in thighs underwent T1-weighted spin-echo imaging before injection and 5-60 minutes and 24 hours after injection of the Gd-DTPA-PEG polymers or Gd-DTPA at a gadolinium dose of 0.1 mmol/kg. Tumor region-of-interest measurements were obtained at each time point to determine contrast enhancement dynamics. Blood-pool enhancement dynamics were observed for the Gd-DTPA-PEG polymers larger than 20 kd. Polymers smaller than 20 kd displayed dynamics similar to those of the freely diffusible agent Gd-DTPA. Above the 20 kd threshold, tumor enhancement was more rapid for smaller polymers. The authors conclude that the 21.9-kd Gd-DTPA-PEG polymer is best suited for clinical MR imaging.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 18 条
  • [1] ARTURSON G, 1964, SCAND J CLIN LAB INV, V1, P81
  • [2] USE OF MR IMAGING CONTRAST AGENTS IN THE BRAIN
    BRADLEY, WG
    YUH, WTC
    BYDDER, GM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01): : 199 - 218
  • [3] MACROMOLECULAR MAGNETIC-RESONANCE-IMAGING CONTRAST-MEDIA - ACCUMULATED EXPERIENCE
    BRASCH, RC
    MOSELEY, ME
    DUPON, J
    WANG, SC
    AICHER, KP
    WIKSTROM, M
    SCHMIEDL, U
    WOLFE, CL
    OGAN, MD
    GROOD, W
    PAAJANEN, H
    WHITE, D
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 : S51 - S52
  • [4] RATIONALE AND APPLICATIONS FOR MACROMOLECULAR GD-BASED CONTRAST AGENTS
    BRASCH, RC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) : 282 - 287
  • [5] BRASCH RC, 1992, RADIOLOGY, V183, P1
  • [6] APPLICATION OF CONTRAST AGENTS IN MR IMAGING OF THE SPINE
    FULBRIGHT, R
    ROSS, JS
    SZE, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01): : 219 - 232
  • [7] MICROVASCULAR PERMEABILITY OF NORMAL AND NEOPLASTIC TISSUES
    GERLOWSKI, LE
    JAIN, RK
    [J]. MICROVASCULAR RESEARCH, 1986, 31 (03) : 288 - 305
  • [8] GRANGER DN, 1983, PHYSL PHARM MICROCIR, V1, P157
  • [9] NUGENT LJ, 1984, CANCER RES, V44, P238
  • [10] ALBUMIN LABELED WITH GD-DTPA AS AN INTRAVASCULAR, BLOOD POOL ENHANCING AGENT FOR MR IMAGING - BIODISTRIBUTION AND IMAGING STUDIES
    SCHMIEDL, U
    OGAN, M
    PAAJANEN, H
    MAROTTI, M
    CROOKS, LE
    BRITO, AC
    BRASCH, RC
    [J]. RADIOLOGY, 1987, 162 (01) : 205 - 210