DETERMINATION OF ANIONS WITH CAPILLARY ELECTROPHORESIS AND INDIRECT ULTRAVIOLET DETECTION

被引:56
作者
RHEMREVBOOM, MM
机构
[1] CASE Lab, 7811 KL Emmen
关键词
D O I
10.1016/0021-9673(94)85168-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is validated for the determination of anions with capillary electrophoresis (CE) in combination with indirect UV detection. The method described here is used for the analysis of eight of the most common anions (fluoride, chloride, bromide, sulphate, nitrate, nitrite, thiosulphate and phosphate). Next, the method is compared with a another buffer system for the determination of anions with CE and indirect UV detection. Typical limits of detection are obtained between 1 and 3 mg/l for the above-mentioned compounds. The repeatability and reproducibility of the system differs per compound and is, with the exception of fluoride and phosphate, between 4 and 6% and 5-10%, respectively. Linearity was observed between 1 and 10 mg/l. The method is applied for the determination of anions in drinking water, serum and urine.
引用
收藏
页码:675 / 684
页数:10
相关论文
共 16 条
  • [1] USE OF A DOUBLE-DETECTOR SYSTEM FOR THE MEASUREMENT OF MOBILITIES IN ZONE ELECTROPHORESIS
    BECKERS, JL
    VERHEGGEN, TPEM
    EVERAERTS, FM
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 452 : 591 - 600
  • [2] INDIRECT PHOTOMETRIC DETECTION IN CAPILLARY ZONE ELECTROPHORESIS
    FORET, F
    FANALI, S
    OSSICINI, L
    BOCEK, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 470 (01): : 299 - 308
  • [3] INDIRECT FLUORIMETRIC DETECTION AND QUANTIFICATION IN CAPILLARY ZONE ELECTROPHORESIS OF INORGANIC ANIONS AND NUCLEOTIDES
    GROSS, L
    YEUNG, ES
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 169 - 178
  • [4] QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION
    HUANG, XH
    LUCKEY, JA
    GORDON, MJ
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (07) : 766 - 770
  • [5] JANDIK P, 1991, LC GC-MAG SEP SCI, V9, P634
  • [6] VARIOUS APPROACHES TO ANALYSIS OF DIFFICULT SAMPLE MATRICES OF ANIONS USING CAPILLARY ION ELECTROPHORESIS
    JONES, WR
    JANDIK, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 385 - 393
  • [7] CONTROLLED CHANGES OF SELECTIVITY IN THE SEPARATION OF IONS BY CAPILLARY ELECTROPHORESIS
    JONES, WR
    JANDIK, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2): : 445 - 458
  • [8] OPTIMIZATION OF SENSITIVITY AND SEPARATION IN CAPILLARY ZONE ELECTROPHORESIS WITH INDIRECT FLUORESCENCE DETECTION
    KUHR, WG
    YEUNG, ES
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (23) : 2642 - 2646
  • [9] LAUER HH, 1992, FEB INT S HIGH PERF
  • [10] HIGH-PERFORMANCE ZONE ELECTROPHORESIS
    MIKKERS, FEP
    EVERAERTS, FM
    VERHEGGEN, TPEM
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB): : 11 - 20