SIMULTANEOUS MEASUREMENT OF REDUCED AND OXIDIZED GLUTATHIONE IN HUMAN AQUEOUS-HUMOR AND CATARACTS BY ELECTROCHEMICAL DETECTION

被引:20
作者
CHAKRAPANI, B [1 ]
YEDAVALLY, S [1 ]
LEVERENZ, V [1 ]
GIBLIN, FJ [1 ]
REDDY, VN [1 ]
机构
[1] OAKLAND UNIV,EYE RES INST,ROCHESTER,MI 48309
关键词
GLUTATHIONE; OXIDIZED GLUTATHIONE; ELECTROCHEMICAL DETECTION; LENS CORTEX; LENS NUCLEUS; EPITHELIUM; HUMAN CATARACT; HYDROGEN PEROXIDE; OXIDATION; AQUEOUS HUMOR;
D O I
10.1159/000267843
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A sensitive, electrochemical method was employed for the simultaneous measurement of reduced and oxidized glutathione in lens cortex, nucleus and capsule epithelia of rabbit lenses, normal human lenses and human cataracts. In addition, aqueous humor from cataract patients was also analyzed. The level of GSSG in the nucleus of human cataracts was significantly higher than that in the nucleus of normal eye bank lenses. The capsule epithelium of intracapsular extracted cataracts possessed high levels of reduced glutathione, despite the fact that much of the glutathione in the cortex and nucleus of the lenses was depleted. Levels of GSH in the aqueous humor of cataract patients were several times higher than those reported for normal aqueous humor. Electrochemical detection proved to be a useful technique for analysis of reduced and oxidized glutathione in lens and aqueous humor, especially when sampled size is small, such as for capsule epithelium.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 16 条
[1]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[2]   THIOL AND DISULFIDE DETERMINATION BY FREE ZONE CAPILLARY ELECTROPHORESIS [J].
CAPPIELLO, M ;
DELCORSO, A ;
CAMICI, M ;
MURA, U .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1993, 26 (04) :335-341
[3]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR REDUCED AND OXIDIZED GLUTATHIONE IN EMBRYONIC, NEONATAL, AND ADULT TISSUES USING A POROUS GRAPHITE ELECTROCHEMICAL DETECTOR [J].
CARROCIAMPI, G ;
HUNT, PG ;
TURNER, CJ ;
WELLS, PG .
JOURNAL OF PHARMACOLOGICAL METHODS, 1988, 19 (01) :75-83
[4]   HPLC ANALYSIS OF LENS GSH AND GSSG [J].
CHANEY, WG ;
SPECTOR, A .
CURRENT EYE RESEARCH, 1984, 3 (02) :345-350
[5]  
CHYLACK LT, 1984, INVEST OPHTH VIS SCI, V25, P166
[6]  
GIBLIN FJ, 1976, INVEST OPHTH VISUAL, V15, P381
[7]  
GIBLIN FJ, 1988, INVEST OPHTH VIS SCI, V29, P1312
[8]   DETERMINATION OF OXIDIZED, REDUCED AND PROTEIN-BOUND GLUTATHIONE IN EYE LENSES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION [J].
OZCIMDER, M ;
LOUTER, AJH ;
LINGEMAN, H ;
VOOGT, WH ;
FREI, RW ;
BLOEMENDAL, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :19-28
[9]  
REDDY DVN, 1962, INVEST OPHTH VISUAL, V1, P635
[10]   GLUTATHIONE AND ITS FUNCTION IN THE LENS - AN OVERVIEW [J].
REDDY, VN .
EXPERIMENTAL EYE RESEARCH, 1990, 50 (06) :771-778