PROTOTYPE DESIGN, CONSTRUCTION AND TEST OF A PB/SCINTILLATOR SAMPLING CALORIMETER WITH WAVELENGTH SHIFTER FIBER OPTIC READOUT

被引:8
作者
BENVENUTI, A
GIORDANO, V
GUERZONI, M
NAVARRIA, FL
CAMPORESI, T
VAZ, P
ALVSVAAG, SJ
MAELAND, OA
KLOVNING, A
RONGVED, R
READ, AL
BJARNE, J
HEDBERG, V
JARLSKOG, G
KRONKVIST, I
CASSIO, V
GAMBA, D
TORASSA, E
VALLAZZA, E
ZANINI, L
LANCERI, L
DELLARICCA, G
POROPAT, P
BONESINI, M
NEGRI, P
PAGANONI, M
GOMES, A
MAIO, A
PERALTA, L
PIMENTA, M
TOME, B
BITIOUKOV, S
GUMENYUK, S
KARIUKHINE, A
LAPIN, V
OBRAZTSOV, V
OSTANKOV, A
PETROVICK, L
PROTOPOPOV, I
SEMENOV, V
ZAITSEV, A
COLLEDANI, D
DULINSKI, W
TURCHETTA, R
机构
[1] INFN,BOLOGNA,ITALY
[2] CERN,CH-1211 GENEVA 23,SWITZERLAND
[3] UNIV BERGEN,N-5014 BERGEN,NORWAY
[4] UNIV OSLO,OSLO 3,NORWAY
[5] LUND UNIV,S-22101 LUND,SWEDEN
[6] UNIV TURIN,I-10124 TURIN,ITALY
[7] INFN,TURIN,ITALY
[8] INFN,TRIESTE,ITALY
[9] UNIV TRIESTE,TRIESTE,ITALY
[10] INFN,MILAN,ITALY
[11] UNIV MILAN,I-20122 MILAN,ITALY
[12] LIP,LISBON,PORTUGAL
[13] FCUL,IST,LISBON,PORTUGAL
[14] IHEP,SERPHUKHOV,RUSSIA
[15] LEPSI,STRASBOURG,FRANCE
关键词
D O I
10.1109/23.256612
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A prototype for the new DELPHI luminosity monitor has been built and tested. The scope of this prototype was to measure the response of the proposed calorimeter in the region which is most critical for the luminosity measurement, i.e. at the inner edge of the acceptance. The aim of the new luminosity monitor is to measure the LEP luminosity with per mill systematic uncertainty: this requires experimental biases at the level of 50 mum or less in the definition of the fiducial volume. Even though we plan to use a tungsten mask to define the inner edge of the acceptance, the calorimeter was designed to match intrinsically this kind of accuracy. A relatively good energy resolution is a must to be able to reject the accidental Bhabha coincidences due to off momentum electrons in LEP. A cut at 80% of the beam energy should reduce this background to less than 1 parts per thousand. The technique used ensures good energy resolution and high spatial uniformity. With the prototype we have already achieved better than 2% uniformity in response and an energy resolution of 3% at 45 GeV.
引用
收藏
页码:537 / 545
页数:9
相关论文
共 10 条
  • [1] LEAD SCINTILLATOR ELECTROMAGNETIC CALORIMETER WITH WAVELENGTH SHIFTING FIBER READOUT
    ATOYAN, GS
    GLADYSHEV, VA
    GNINENKO, SN
    ISAKOV, VV
    KOVZELEV, AV
    MONICH, EA
    POBLAGUEV, AA
    PROSKURYAKOV, AL
    SEMENYUK, IN
    LAPSHIN, VG
    PROTOPOPOV, YV
    RYKALIN, VI
    SEMENOV, VK
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) : 144 - 154
  • [2] BARICHETTO G, 1987, NUCL INSTR METH A, V254
  • [3] BRENNER R, 1992, 6TH EUR S SEM DET MI
  • [4] BRUN R, 1987, DDEE811 CERN
  • [5] CHARPENTIER P, P CHEP 91 TSUKUBA, P643
  • [6] COLELDANI M, IN PRESS HIGH RESOLU
  • [7] A SCINTILLATOR LEAD PHOTON CALORIMETER USING OPTICAL FIBER READOUT SYSTEMS
    FESSLER, H
    FREUND, P
    GEBAUER, J
    GLAS, KM
    PRETZL, KP
    SEYBOTH, P
    SEYERLEIN, J
    THEVENIN, JC
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 240 (02) : 284 - 288
  • [8] JONKER M, P CHEP91 TSUKUBA, P619
  • [9] THE MULTIPLEXED ADC SYSTEM AND THE FASTBUS READOUT FOR THE DELPHI FORWARD ELECTROMAGNETIC CALORIMETER
    LIPPI, I
    MAZZUCATO, M
    PEGORARO, M
    PERNICKA, M
    ZUMERLE, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (1-2) : 243 - 250
  • [10] LOHER B, 1987, NUCL INSTRUM METH A, V254, P26