DIRECT IMAGING RAMAN MICROSCOPE BASED ON TUNABLE WAVELENGTH EXCITATION AND NARROW-BAND EMISSION DETECTION

被引:91
作者
PUPPELS, GJ [1 ]
GROND, M [1 ]
GREVE, J [1 ]
机构
[1] UNIV TWENTE,DEPT APPL PHYS,POB 217,7500 AE ENSCHEDE,NETHERLANDS
关键词
RAMAN MICROSCOPY; IMAGING; CHARGE-COUPLED DEVICE; DYE LASER; DIELECTRIC FILTERS; FLUORESCENCE MICROSCOPY;
D O I
10.1366/0003702934068017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new type of imaging Raman microscope is described. First the advantages and disadvantages of the two possible approaches to Raman microscopy based on signal detection by means of a charge-coupled-device camera (i.e., direct imaging and image reconstruction) are discussed. Arguments are given to show that in most cases direct imaging is to be preferred over image reconstruction, because it provides the desired information in less time. In the direct imaging Raman microscope presented in this communication, detection of scattered light occurs in a narrow interval around a fixed wavelength. Selection of the Raman wavenumber shift at which an image is recorded is established by tuning the wavelength of the exciting laser light in such a way that the wavelength of the Raman scattered light with the desired Raman shift coincides with the detected wavelength. The microscope has been incorporated in a Raman microspectrometer in a way that enables easy switching between the imaging and the multichannel spectroscopy modes of operation. Bright field, fluorescence, and Raman microscopic images can be obtained.
引用
收藏
页码:1256 / 1267
页数:12
相关论文
共 18 条
  • [1] BARBILLAT J, 1992, 13TH P ICORS, P1074
  • [2] A COMPACT RAMAN MICROPROBE MICROSCOPE - ANALYSIS OF POLYDIACETYLENE LANGMUIR AND LANGMUIR-BLODGETT-FILMS
    BATCHELDER, DN
    CHENG, C
    MULLER, W
    SMITH, BJE
    [J]. MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1991, 46 : 171 - 179
  • [3] Bell R. J., 1972, INTRO FOURIER TRANSF
  • [4] LINE-SCANNED MICRO RAMAN-SPECTROSCOPY USING A COOLED CCD IMAGING DETECTOR
    BOWDEN, M
    GARDINER, DJ
    RICE, G
    GERRARD, DL
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 1990, 21 (01) : 37 - 41
  • [5] CHASE DB, 1991, ANAL RAMAN SPECTROSC, P21
  • [6] RAMAN MICROPROBE AND MICROSCOPE WITH LASER EXCITATION
    DELHAYE, M
    DHAMELINCOURT, P
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 1975, 3 (01) : 33 - 43
  • [7] MULTISPECTRAL HADAMARD-TRANSFORM RAMAN MICROSCOPY
    LIU, KLK
    CHEN, LH
    SHENG, RS
    MORRIS, MD
    [J]. APPLIED SPECTROSCOPY, 1991, 45 (10) : 1717 - 1720
  • [8] CAROTENOIDS LOCATED IN HUMAN LYMPHOCYTE SUBPOPULATIONS AND NATURAL-KILLER-CELLS BY RAMAN MICROSPECTROSCOPY
    PUPPELS, GJ
    GARRITSEN, HSP
    KUMMER, JA
    GREVE, J
    [J]. CYTOMETRY, 1993, 14 (03): : 251 - 256
  • [9] STUDYING SINGLE LIVING CELLS AND CHROMOSOMES BY CONFOCAL RAMAN MICROSPECTROSCOPY
    PUPPELS, GJ
    DEMUL, FFM
    OTTO, C
    GREVE, J
    ROBERTNICOUD, M
    ARNDTJOVIN, DJ
    JOVIN, TM
    [J]. NATURE, 1990, 347 (6290) : 301 - 303
  • [10] DESCRIPTION AND PERFORMANCE OF A HIGHLY SENSITIVE CONFOCAL RAMAN MICROSPECTROMETER
    PUPPELS, GJ
    COLIER, W
    OLMINKHOF, JHF
    OTTO, C
    DEMUL, FFM
    GREVE, J
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 1991, 22 (04) : 217 - 225