COMPARISON OF STABLE ISOTOPES AND RADIOISOTOPES IN THE MEASUREMENT OF IRON-ABSORPTION IN HEALTHY WOMEN

被引:24
作者
BARRETT, JFR
WHITTAKER, PG
FENWICK, JD
WILLIAMS, JG
LIND, T
机构
[1] UNIV NEWCASTLE UPON TYNE, ROYAL VICTORIA HOSP, DEPT OBSTET & GYNAECOL, NEWCASTLE UPON TYNE, TYNE & WEAR, ENGLAND
[2] NEWCASTLE GEN HOSP, DEPT PHYS MED, NEWCASTLE UPON TYNE, TYNE & WEAR, ENGLAND
[3] UNIV LONDON IMPERIAL COLL SCI & TECHNOL, NERC, ICP MS FACIL, ASCOT, BERKS, ENGLAND
关键词
ABSORPTION; FEMALE; IRON ISOTOPES; MASS SPECTRUM ANALYSIS; WHOLE BODY COUNTING;
D O I
10.1042/cs0870091
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. Stable isotope methods are being used to investigate the absorption of dietary iron. In order to be certain that this new methodology is accurate, we have compared results obtained using stable isotopes and inductively coupled plasma mass spectrometry with those determined using a radioisotope and whole body counting. 2. The stable isotope Fe-54 (2.8mg) was given to 10 healthy non-pregnant women. Six women received the isotope in aqueous form, and four took it with a meat meal. The Fe-54 served as a carrier for 10ng of the radioisotope Fe-59. An ampoule (200 mu g) of the isotope Fe-57 or Fe-58 was then given intravenously, and in serum samples taken over the next 10 h the ratios of the stable iron isotopes were measured by inductively coupled plasma mass spectrometry and the oral iron absorption was calculated. This was then compared with the results obtained by using a whole body counter to measure (on day 0 and day 14) the gamma-activity emitted by the radioisotope. 3. The mean iron absorption measured by both methods ranged from 8% to 45%. Measurement of the post-absorptive serum enrichment of the stable isotopes provided estimates of absorption from both aqueous and food iron which were similar to that yielded by whole body counting, the mean difference being -1.5% (95% confidence interval -5.2 to 2.1%). Absorption estimated by stable isotopes exhibited the same inverse relationship with the serum ferritin level (body iron stores) to that known to exist with whole body counting. Similar estimates of food iron absorption were obtained irrespective of the type of isotope used as an extrinsic label, implying that stable isotopes are as valid as radioisotopes in reflecting intrinsic food iron absorption. 4. This study validates the use of stable isotopes and post-absorption curves as a new and accurate technique in the measurement of iron absorption.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 27 条
[1]  
BJORNRASMUSSEN E, 1973, AM J CLIN NUTR, V26, P1311
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   INABILITY TO ASSESS ABSORPTION OF IRON FROM PLASMA RADIOIRON CURVES [J].
BOTHWELL, TH ;
MALLETT, B ;
OLIVER, R ;
SMITH, MD .
BRITISH JOURNAL OF HAEMATOLOGY, 1955, 1 (04) :352-357
[4]  
BOTHWELL TH, 1979, IRON METABOLISM MAN, P425
[5]  
BRISE H, 1962, ACTA MED SCAND, V171, P23
[6]  
Charlton R. W., 1977, Proteins of iron metabolism, P387
[7]   FOOD IRON-ABSORPTION MEASURED BY AN EXTRINSIC TAG [J].
COOK, JD ;
FINCH, CA ;
WALKER, R ;
MARTINEZ.C ;
LAYRISSE, M ;
MONSEN, E .
JOURNAL OF CLINICAL INVESTIGATION, 1972, 51 (04) :805-+
[8]   SERUM FERRITIN AS A MEASURE OF IRON STORES IN NORMAL SUBJECTS [J].
COOK, JD ;
LIPSCHIT.DA ;
MILES, LEM ;
FINCH, CA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1974, 27 (07) :681-687
[9]  
DELAETER JR, 1991, PURE APPL CHEM, V63, P991
[10]  
Ekenved G, 1976, Scand J Haematol Suppl, V28, P31