Elements of biosensor construction

被引:57
作者
Davis, J
Vaughan, DH
Cardosi, MF
机构
[1] UNIV PAISLEY,DEPT CHEM & CHEM ENGN,PAISLEY PA1 2BE,RENFREW,SCOTLAND
[2] UNIV PAISLEY,DEPT BIOL SCI,PAISLEY PA1 2BE,RENFREW,SCOTLAND
关键词
biosensors; review; enzyme electrodes; mediators; polymers;
D O I
10.1016/0141-0229(95)00013-5
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The diverse configurations observed in amperometric biosensors can be attributed to the manipulation of several interrelated elements in the construction of these devices. This article highlights these elements and identifies approaches taken and the factors influencing the choice of the approaches. The results of a systematic literature review over a 2.5-year period (18 May 1992-21 November 1994) encompassing all of the elements in biosensor construction are used to evaluate the prevalence, and hence, acceptance of recent approaches with critical analysis applied to certain techniques. Future trends are predicted and possible directions discussed.
引用
收藏
页码:1030 / 1035
页数:6
相关论文
共 12 条
[1]   INTRAMOLECULAR ELECTRON-TRANSFER RATES IN FERROCENE-DERIVATIZED GLUCOSE-OXIDASE [J].
BADIA, A ;
CARLINI, R ;
FERNANDEZ, A ;
BATTAGLINI, F ;
MIKKELSEN, SR ;
ENGLISH, AM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) :7053-7060
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .4. COIMMOBILIZATION OF GLUCOSE-OXIDASE AND FERRO FERRICYANIDE IN POLY(NORMAL-METHYLPYRROLE) FILMS [J].
BARTLETT, PN ;
ALI, Z ;
EASTWICKFIELD, V .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1992, 88 (18) :2677-2683
[3]   ENZYME SWITCH RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1118-1119
[4]  
CARDOSI MF, 1993, ELECTROANAL, V5, P89
[5]   AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE [J].
CESPEDES, F ;
MARTINEZFABREGAS, E ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1993, 284 (01) :21-26
[6]   CONTROLLED ELECTROCHEMICAL PREPARATION OF ENZYMATIC LAYERS FOR THE DESIGN OF AMPEROMETRIC BIOSENSORS [J].
COCHEGUERENTE, L ;
COSNIER, S ;
INNOCENT, C ;
MAILLEY, P ;
MOUTET, JC ;
MORELIS, RM ;
LECA, B ;
COULET, PR .
ELECTROANALYSIS, 1993, 5 (08) :647-652
[7]   EVIDENCE FOR THE FUNCTIONAL MECHANISM OF A POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
COOPER, JM ;
BLOOR, D .
ELECTROANALYSIS, 1993, 5 (9-10) :883-886
[8]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[9]  
HILL HAO, 1990, BISOENSOR PRACTICAL, P32
[10]   PENICILLIN SENSOR BASED ON A MICROARRAY ELECTRODE COATED WITH PH-RESPONSIVE POLYPYRROLE [J].
NISHIZAWA, M ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2642-2644