POLYMER ENCAPSULATED PACKING MATERIAL FOR RESERVED PHASE LIQUID-CHROMATOGRAPHY

被引:25
作者
ZUO, YM [1 ]
ZHU, BR [1 ]
LIAO, Y [1 ]
GUI, MD [1 ]
PANG, ZL [1 ]
QI, JX [1 ]
机构
[1] TIANJIN 2 CHEM REAGENT FACTORY,TIANJIN 300210,PEOPLES R CHINA
关键词
COLUMN LIQUID CHROMATOGRAPHY; POLYMER ENCAPSULATED PACKINGS; POLY(ETHYLSTRENE-DIVINYLBENZENE); PREPARATION AND EVALUATION;
D O I
10.1007/BF02269632
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A series of polymer-encapsulated packing materials for reversed phase high-performance liquid chromatography was prepared by radical polymerization of ethylstyrene and divinylbenzene with vinyl-modified silica in solutions. Some characteristics such as polymer structure, swelling propensity, residual silanols, column efficiency and retention properties were evaluated. Such material is easy to pack and yields high column efficiencies. Its superior performance for the separation of mixtures of aromatic hydrocarbons, amino- and hydroxyl group containing compounds are demonstrated by several examples.
引用
收藏
页码:756 / 760
页数:5
相关论文
共 11 条
[1]   CHROMATOGRAPHIC CHARACTERISTICS OF POLYMER-BASED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PACKINGS [J].
DAWKINS, JV ;
LLOYD, LL ;
WARNER, FP .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :157-167
[2]   POLYMER ENCAPSULATED STATIONARY PHASES - ADVANTAGES, PROPERTIES AND SELECTIVITIES [J].
ENGELHARDT, H ;
LOW, H ;
EBERHARDT, W ;
MAUSS, M .
CHROMATOGRAPHIA, 1989, 27 (11-12) :535-543
[3]   SYNTHESIS AND CHARACTERIZATION OF STATIONARY PHASES ON THE BASIS OF SILICAS MODIFIED WITH EPOXIDIZED POLYBUTADIENES .4. CHROMATOGRAPHIC EXPERIMENTS ON A NEW AMINO-FUNCTIONALIZED STATIONARY PHASE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ERLER, U ;
HEUBLEIN, G .
JOURNAL OF CHROMATOGRAPHY, 1991, 588 (1-2) :340-343
[4]   NEW POLYMER COATED ANION-EXCHANGE HPLC-PHASES - IMMOBILIZATION OF POLY (2-HYDROXY, 3N-ETHYLENEDIAMINO) BUTADIENE ON SILICA AND ALUMINA [J].
HEINEMANN, G ;
KOHLER, J ;
SCHOMBURG, G .
CHROMATOGRAPHIA, 1987, 23 (06) :435-441
[5]   DETERMINATION OF SURFACE SILANOLS OF SILICA-GELS AND HPLC BONDED PHASES [J].
KHURANA, AL ;
HO, CT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (15) :3205-3211
[6]   TOLUENE POLYMER AS A NEW STATIONARY PHASE IN REVERSED-PHASE COLUMN LIQUID-CHROMATOGRAPHY [J].
NASUTO, R ;
KWIETNIEWSKI, L .
CHROMATOGRAPHIA, 1990, 29 (11-12) :597-602
[7]   SWELLING PROPENSITY (SP FACTOR) OF SEMIRIGID CHROMATOGRAPHIC PACKING MATERIALS [J].
NEVEJANS, F ;
VERZELE, M .
JOURNAL OF CHROMATOGRAPHY, 1985, 350 (01) :145-150
[8]   POLYMER COATED STATIONARY PHASES FOR LIQUID-CHROMATOGRAPHY [J].
OHMACHT, R ;
KELE, M ;
MATUS, Z .
CHROMATOGRAPHIA, 1989, 28 (1-2) :19-23
[9]   STRUCTURES AND CHROMATOGRAPHIC CHARACTERISTICS OF CAPSULE-TYPE SILICA-GELS COATED WITH HYDROPHOBIC POLYMERS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
OHTSU, Y ;
FUKUI, H ;
KANDA, T ;
NAKAMURA, K ;
NAKANO, M ;
NAKATA, O ;
FUJIYAMA, Y .
CHROMATOGRAPHIA, 1987, 24 :380-384
[10]   IMMOBILIZATION OF STATIONARY LIQUIDS ON SILICA PARTICLES BY GAMMA-RADIATION [J].
SCHOMBURG, G ;
KOHLER, J ;
FIGGE, H ;
DEEGE, A ;
BIENVOGELSANG, U .
CHROMATOGRAPHIA, 1984, 18 (05) :265-279