PRECISION RESPONSE ESTIMATION, ENERGY CALIBRATION, AND UNFOLDING OF SPECTRA MEASURED WITH A LARGE NAI DETECTOR

被引:9
作者
FADDEGON, BA [1 ]
VANDERZWAN, L [1 ]
ROGERS, DWO [1 ]
ROSS, CK [1 ]
机构
[1] NATL RES COUNCIL CANADA, DIV PHYS, OTTAWA K1A 0R6, ONTARIO, CANADA
关键词
D O I
10.1016/0168-9002(91)90748-F
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Methods are evaluated for determining the energy calibration and the response of a 20 cm by 25 cm NaI detector, and for unfolding the detector response from measured spectra of 10 to 30 MV bremsstrahlung. A set of measured gamma-ray and electron spectra with energies ranging from 1 to 30 MeV were fit to response functions calculated using Monte Carlo techniques (EGS4) to determine the energy calibration of the spectrometer and the degree of broadening required for the calculated response functions. For electrons, the broadened response was in excellent agreement with the measurements. For gamma-rays, there was evidence of collimator-degraded photons in the measured spectra. A matrix of broadened response-functions was generated for use in unfolding bremsstrahlung spectra in the energy range of 0.2 to 35 MeV. The unfolding routine FERDO was shown to provide reliable estimates of the spectrum of photons in the bremsstrahlung beam when this response matrix was used for unfolding. Collimator effects were ignored without significantly affecting the shape of the unfolded spectrum.
引用
收藏
页码:138 / 149
页数:12
相关论文
共 37 条
[1]   COLLIMATOR-PRODUCED ENERGY DEGRADATION OF MEGAVOLTAGE X-RAYS [J].
AMOLS, HI ;
RUBIN, A ;
PECK, RA .
MEDICAL PHYSICS, 1984, 11 (04) :521-524
[2]  
[Anonymous], [No title captured]
[3]   RESPONSE FUNCTIONS FOR SODIUM IODIDE SCINTILLATION DETECTORS [J].
BERGER, MJ ;
SELTZER, SM .
NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (02) :317-&
[4]   DETECTION OF 50-MEV GAMMA-RAYS WITH A LARGE MODULARIZED NAI(TL) DETECTOR [J].
CARRINGTON, RL ;
EICHLER, RA ;
HOFSTADTER, R ;
HUGHES, EB ;
ROLFE, J ;
MCPHARLIN, TP ;
BOWMAN, JD ;
COOPER, MD ;
HAMM, ME ;
HOFFMAN, CM ;
MISCHKE, RE ;
NAGLE, DE ;
SARRACINO, JS ;
THOMPSON, PA ;
ANDERSON, HL ;
KINNISON, WW ;
MATIS, HS ;
WRIGHT, SC .
NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (01) :203-220
[5]   DESIGN AND PERFORMANCE OF A MODULARIZED NAI(TL) DETECTOR (CRYSTAL BALL PROTOTYPE) [J].
CHAN, Y ;
PARTRIDGE, RA ;
PECK, CW ;
KOLLMAN, W ;
RICHARDSON, M ;
STRAUCH, K ;
ASCHMAN, D ;
COYNE, DG ;
BERON, BL ;
CARRINGTON, RL ;
EICHLER, RA ;
HOFSTADTER, R ;
HUGHES, EB ;
KIRKBRIDGE, GI ;
LIBERMAN, AD ;
OREILLY, J ;
PARKS, R ;
ROLFE, J ;
SIMPSON, JW ;
TOMPKINS, JC ;
BAUMGARTEN, A ;
BERNSTEIN, J ;
BLOOM, ED ;
BULOS, F ;
DILLON, J ;
GAISER, J ;
GODFREY, GL ;
HALL, J ;
KIESLING, C ;
OREGLIA, M ;
PFAU, D ;
ROYDEN, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) :333-339
[6]   THE RESPONSE FUNCTION OF LARGE NAI DETECTORS TO HIGH-ENERGY PHOTONS [J].
CORVISIERO, P ;
TAIUTI, M ;
ZUCCHIATTI, A ;
ANGHINOLFI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3) :291-297
[7]   THE RESOLUTION CORRECTION IN THE SCINTILLATION SPECTROMETRY OF CONTINUOUS X-RAYS [J].
DIXON, WR ;
AITKEN, JH .
CANADIAN JOURNAL OF PHYSICS, 1958, 36 (12) :1624-1633
[8]   THE RESPONSE OF A 24CMX36CM NAI(TL) SPECTROMETER TO GAMMA-RAYS BETWEEN 50 AND 300 MEV [J].
DOWELL, DH ;
ZIEGLER, WP ;
SANDORFI, AM ;
ZIEGLER, B ;
SCHOCH, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 254 (03) :570-577
[9]   DOSIMETRY OF A NEARLY MONOENERGETIC 6 TO 7 MEV PHOTON SOURCE BY NAI(TL) SCINTILLATION SPECTROMETRY [J].
DUVALL, KC ;
SELTZER, SM ;
SOARES, CG ;
RUST, BW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (03) :866-870
[10]   FORWARD-DIRECTED BREMSSTRAHLUNG OF 10-MEV TO 30-MEV ELECTRONS INCIDENT ON THICK TARGETS OF AL AND PB [J].
FADDEGON, BA ;
ROSS, CK ;
ROGERS, DWO .
MEDICAL PHYSICS, 1990, 17 (05) :773-785