CAPILLARY ISOELECTRIC-FOCUSING - A ROUTINE METHOD FOR PROTEIN-ANALYSIS

被引:29
作者
SCHWER, C
机构
[1] Max-Planck-Institute for Biochemistry, Martinsried
关键词
CAPILLARY ISOELECTRIC FOCUSING; PROTEINS; MONOCLONAL ANTIBODY;
D O I
10.1002/elps.11501601342
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although isoelectric focusing (IEF) in the slab gel format is a widely used technique in protein analysis, capillary isoelectric focusing (CIEF) is not yet a method used routinely, despite major advantages. This may be due to the fact that several methods for performing IEF in the capillary can be found in the literature, differing in the manner of mobilizing the focused protein zones for detection. We therefore discuss and compare the three most widely used CIEF techniques - using chemical, pressure, or electroosmotic flow (EOF) mobilization - with respect to linearity of the calibration curve, resolution, and reproducibility.
引用
收藏
页码:2121 / 2126
页数:6
相关论文
共 18 条
[1]   ISOELECTRIC-FOCUSING BY FREE SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, SM ;
WIKTOROWICZ, JE .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :84-90
[2]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[3]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[4]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[5]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[6]   ISOELECTRIC-FOCUSING OF PROTEINS IN CAPILLARY ELECTROPHORESIS WITH PRESSURE-DRIVEN MOBILIZATION [J].
HUANG, TL ;
SHIEH, PCH ;
COOKE, N .
CHROMATOGRAPHIA, 1994, 39 (9-10) :543-548
[7]   FAST AND HIGH-RESOLUTION ANALYSIS OF HUMAN-SERUM TRANSFERRIN BY HIGH-PERFORMANCE ISOELECTRIC-FOCUSING IN CAPILLARIES [J].
KILAR, F ;
HJERTEN, S .
ELECTROPHORESIS, 1989, 10 (01) :23-29
[8]   SEPARATION OF THE HUMAN TRANSFERRIN ISOFORMS BY CARRIER-FREE HIGH-PERFORMANCE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING [J].
KILAR, F ;
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :351-357
[9]   CAPILLARY ISOELECTRIC-FOCUSING OF PROTEINS IN UNCOATED FUSED-SILICA CAPILLARIES USING POLYMERIC ADDITIVES [J].
MAZZEO, JR ;
KRULL, IS .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2852-2857
[10]   IMPROVEMENTS IN THE METHOD DEVELOPED FOR PERFORMING ISOELECTRIC-FOCUSING IN UNCOATED CAPILLARIES [J].
MAZZEO, JR ;
KRULL, IS .
JOURNAL OF CHROMATOGRAPHY, 1992, 606 (02) :291-296