PRESENT STATE OF THE COMPARISON BETWEEN RADIOMETRIC SCALES BASED ON 3 PRIMARY STANDARDS

被引:37
作者
STOCK, M
FISCHER, J
FRIEDRICH, R
JUNG, HJ
THORNAGEL, R
ULM, G
WENDE, B
机构
[1] Physikalisch-Technische Bundesanstalt, D-10587 Berlin
关键词
D O I
10.1088/0026-1394/30/4/041
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the PTB radiometric scales are compared which are based on electrodynamics (electron storage ring BESSY), on thermodynamics (black body of known temperature T90 of the international Temperature Scale) and on a thermal detector in combination with the electrical substitution principle (cryogenic radiometer). The uncertainty contributions of the different input parameters for establishing the independent radiometric scales are analysed in detail. According to this analysis spectral radiant powers in the visible are realized or expected to be realized (black body) with uncertainties (1 sigma level) of 0,10 % (BESSY), of 0,07 % (black body, lambda > 650 nm) and of 0,007 % (cryogenic radiometer). Filter radiometers calibrated at the three independent primary standards are used as transfer instruments for the comparison. The measured values of the responsivities of the filter radiometers are estimated to be uncertain by 0,11 % (BESSY), 0,08 % (black body, lambda > 650 nm), and 0,03 % (cryogenic radiometer). Preliminary experimental results of the comparison between BESSY and the cryogenic radiometer are in agreement with the uncertainty analysis.
引用
收藏
页码:439 / 449
页数:11
相关论文
共 35 条
[1]   HIGHLY STABLE, MONOCHROMATIC AND TUNABLE OPTICAL RADIATION SOURCE AND ITS APPLICATION TO HIGH-ACCURACY SPECTROPHOTOMETRY [J].
ANDERSON, VE ;
FOX, NP ;
NETTLETON, DH .
APPLIED OPTICS, 1992, 31 (04) :536-545
[2]   A NEW DETECTOR-BASED SPECTRAL EMISSION SCALE [J].
ANDERSON, VE ;
FOX, NP .
METROLOGIA, 1991, 28 (03) :135-139
[3]   ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION [J].
ARNOLD, D ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1539-1542
[4]   PRECISE MEASUREMENT OF STEFAN-BOLTZMANN CONSTANT [J].
BLEVIN, WR ;
BROWN, WJ .
METROLOGIA, 1971, 7 (01) :15-&
[5]   DIFFRACTION CORRECTIONS IN RADIOMETRY - COMPARISON OF 2 DIFFERENT METHODS OF CALCULATION [J].
BOIVIN, LP .
APPLIED OPTICS, 1975, 14 (08) :2002-2009
[6]   PRESENT STATE OF THE DETERMINATION OF THERMODYNAMIC TEMPERATURES NEAR THE FREEZING-POINT OF SILVER BY ABSOLUTE CRYORADIOMETRY [J].
FISCHER, J ;
LEI, F ;
STOCK, M .
METROLOGIA, 1991, 28 (03) :243-246
[7]   A NONCONTACT MEASUREMENT OF RADIOMETRIC APERTURES WITH AN OPTICAL MICROTOPOGRAPHY SENSOR [J].
FISCHER, J ;
STOCK, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (08) :693-698
[8]   ABSOLUTE SPECTRAL RADIOMETRIC DETERMINATION OF THE THERMODYNAMIC TEMPERATURES OF THE MELTING FREEZING POINTS OF GOLD, SILVER AND ALUMINUM [J].
FOX, NP ;
MARTIN, JE ;
NETTLETON, DH .
METROLOGIA, 1991, 28 (05) :357-374
[9]   COMPARISON OF 2 CRYOGENIC RADIOMETERS BY DETERMINING THE ABSOLUTE SPECTRAL RESPONSIVITY OF SILICON PHOTODIODES WITH AN UNCERTAINTY OF 0.02-PERCENT [J].
FOX, NP ;
MARTIN, JE .
APPLIED OPTICS, 1990, 29 (31) :4686-4693
[10]   TRAP DETECTORS AND THEIR PROPERTIES [J].
FOX, NP .
METROLOGIA, 1991, 28 (03) :197-202