摘要
At the PTB radiometric scales are compared which are based on electrodynamics (electron storage ring BESSY), on thermodynamics (black body of known temperature T90 of the international Temperature Scale) and on a thermal detector in combination with the electrical substitution principle (cryogenic radiometer). The uncertainty contributions of the different input parameters for establishing the independent radiometric scales are analysed in detail. According to this analysis spectral radiant powers in the visible are realized or expected to be realized (black body) with uncertainties (1 sigma level) of 0,10 % (BESSY), of 0,07 % (black body, lambda > 650 nm) and of 0,007 % (cryogenic radiometer). Filter radiometers calibrated at the three independent primary standards are used as transfer instruments for the comparison. The measured values of the responsivities of the filter radiometers are estimated to be uncertain by 0,11 % (BESSY), 0,08 % (black body, lambda > 650 nm), and 0,03 % (cryogenic radiometer). Preliminary experimental results of the comparison between BESSY and the cryogenic radiometer are in agreement with the uncertainty analysis.
引用
收藏
页码:439 / 449
页数:11
相关论文
共 35 条
[11]   INTERCOMPARISON BETWEEN 2 INDEPENDENT PRIMARY RADIOMETRIC STANDARDS IN THE VISIBLE AND NEAR-INFRARED - A CRYOGENIC RADIOMETER AND THE ELECTRON STORAGE RING BESSY [J].
FOX, NP ;
KEY, PJ ;
RIEHLE, F ;
WENDE, B .
APPLIED OPTICS, 1986, 25 (14) :2409-2420
[12]   HIGH-ACCURACY MODELING OF PHOTODIODE QUANTUM EFFICIENCY [J].
GEIST, J ;
BALTES, H .
APPLIED OPTICS, 1989, 28 (18) :3929-3939
[13]   NUMERICAL MODELING OF SILICON PHOTODIODES FOR HIGH-ACCURACY APPLICATIONS .3. INTERPOLATING AND EXTRAPOLATING INTERNAL QUANTUM-EFFICIENCY CALIBRATIONS [J].
GEIST, J ;
ROBINSON, AM ;
JAMES, CR .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1991, 96 (04) :481-492
[14]   RADIOMETRY BASED ON SYNCHROTRON RADIATION FROM THE STORAGE RING VEPP-2M [J].
GLUSKIN, ES ;
KUZMINIKH, VS ;
MAKAROV, OA ;
OGURTSOV, VI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :397-399
[15]   CRYOGENIC RADIOMETERS AND THEIR APPLICATION TO METROLOGY [J].
HOYT, CC ;
FOUKAL, PV .
METROLOGIA, 1991, 28 (03) :163-167
[16]  
JUNG HJ, 1989, CCT8910 DOC, V17
[17]  
Kaase H, 1984, LICHT FORSCHUNG, V6, P29
[18]   COMPARISON OF THE NBS SURF AND TUNGSTEN ULTRAVIOLET IRRADIANCE STANDARDS [J].
KOSTKOWSKI, HJ ;
LEAN, JL ;
SAUNDERS, RD ;
HUGHEY, LR .
APPLIED OPTICS, 1986, 25 (18) :3297-3306
[19]   COMPARISON OF THE NIST SURF AND ARGON MINIARC IRRADIANCE STANDARDS AT 214 NM [J].
LEAN, JL ;
KOSTKOWSKI, HJ ;
SAUNDERS, RD ;
HUGHEY, LR .
APPLIED OPTICS, 1989, 28 (15) :3246-3253
[20]   CHARACTERIZATION OF PHOTODIODES IN THE UV AND VISIBLE SPECTRAL REGION-BASED ON CRYOGENIC RADIOMETRY [J].
LEI, F ;
FISCHER, J .
METROLOGIA, 1993, 30 (04) :297-303