Characterization and application of an on-line flow injection analysis wall-jet electrode system for glucose monitoring during fermentation

被引:9
作者
Huang, YL
Foellmer, TJ
Ang, KC
Khoo, SB
Yap, MGS
机构
[1] NATL UNIV SINGAPORE,DEPT CHEM,SINGAPORE 0511,SINGAPORE
[2] NATL UNIV SINGAPORE,BIOPROC TECHNOL UNIT,SINGAPORE 0511,SINGAPORE
关键词
flow injection; glucose; wall-jet electrode system; fermentation;
D O I
10.1016/0003-2670(95)00388-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line system for glucose monitoring during fermentation was developed. The system employed flow-injection analysis coupled with a wall-jet electrode. Glucose was converted enzymatically in a tubular reactor packed with controlled pore glass beads containing immobilized glucose oxidase. The hydrogen peroxide produced was detected amperometrically. A filtration/sampling module operated by a peristaltic pump enabled sample withdrawal from the fermenter. The system was interfaced to a programmable language controller which was in turn linked to a microcomputer. The dual injection valve of the now system was operated in a novel configuration to achieve sample dilution, by dispersion, and standardization simultaneously. The developed system was characterized for dilution factor, stability and linearity of response. After conditioning of the reactor, sample peak heights were found to have a precision of 1.07% (R.S.D., 25 determinations) when the glucose concentration was 1.32 g l(-1). Under the conditions studied, linear response to glucose concentration from 0.062 to 4.0 g l(-1) was obtained. Sample throughput was about 7 per hour. Interferences from the fermentation media were negligible after filtration through the sampling module and dilution. The on-line system was applied to glucose monitoring during E. coli fermentation. Good results were obtained as shown by the high cell density (OD600m = 168 in 9 h fermentation), constant specific growth rate (mu = 0.66) and lower acetate accumulation (less than 2 g l(-1) when OD600m was over 50).
引用
收藏
页码:223 / 232
页数:10
相关论文
共 18 条
[1]  
AGRAWAL P, 1984, ADV BIOCH ENG BIOTEC, P61
[2]   DETERMINATION OF GLUCOSE IN FERMENTATION PROCESSES BY MEANS OF AN ONLINE COUPLED FLOW-INJECTION SYSTEM USING ENZYME SENSORS BASED ON CHEMICALLY MODIFIED ELECTRODES [J].
APPELQVIST, R ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1990, 235 (02) :265-271
[3]   MONITORING OF SUBSTRATES AND PRODUCTS DURING FED-BATCH PENICILLIN FERMENTATIONS ON COMPLEX MEDIA [J].
CHRISTENSEN, LH ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :123-136
[4]   CELLULAR AND ENVIRONMENTAL FACTORS AFFECTING SYNTHESIS AND EXCRETION OF METABOLITES [J].
DEMAIN, AL .
JOURNAL OF APPLIED CHEMISTRY AND BIOTECHNOLOGY, 1972, 22 (03) :345-&
[5]  
FANG ZL, 1993, FLOW INJECTION SEPAR, P9
[6]  
FRALEIGH S, 1976, TRENDS BIOTECHNOL, V7, P159
[7]   CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS [J].
GREGG, BA ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :258-263
[8]  
HONG ML, 1992, THESIS NATIONAL U SI, P19
[9]  
HUANG YL, 1993, ANAL CHIM ACTA, V283, P763
[10]  
HUANG YL, IN PRESS ELECTROANAL