A MULTIELECTRODE ARRAY FOR COMBINED MICROIONTOPHORESIS AND MULTIPLE SINGLE-UNIT RECORDINGS

被引:16
作者
HAIDARLIU, S [1 ]
SHULZ, D [1 ]
AHISSAR, E [1 ]
机构
[1] INST ALFRED FESSARD,CNRS,GIF SUR YVETTE,FRANCE
基金
以色列科学基金会;
关键词
MULTIELECTRODE ARRAY; COMBINED ELECTRODE; MICROIONTOPHORESIS; MULTIPLE SINGLE-UNIT RECORDING; AUDITORY CORTEX; NEUROMODULATOR; SPIKE SORTING; CROSS-CORRELATION;
D O I
10.1016/0165-0270(94)00114-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A remotely controlled multi-electrode array, equipped with a combined electrode (CE) and 3 regular tungsten in-glass electrodes (TEs) is described. The CE enables ejection of different neuroactive substances from 6 barrels and recording of single-unit activity from the etched tungsten rod placed in the central glass capillary. The CE is prepared with standard tungsten rod, glass-capillaries, and regular micropipette pullers. Such CEs possess a good stiffness-flexibility balance, length, easy cell isolation, high stability of recordings, effective ejection properties, and ability to survive penetration of dura. The efficiency of a 4-electrode array, including the CE, was tested by recording the effects of extracellularly ejected drugs (glutamate, acetylcholine and atropine) on single neurons in the auditory cortex of anesthetized guinea pigs. Induced modifications of single-neuron firing patterns and evoked responses were in agreement with the known effects of individual and combined applications of these drugs. Using this multi-electrode array and spike sorting techniques, the pharmacological environment of up to 12 simultaneously recorded cells can be modulated, and its effect on single neurons and on their interactions can be monitored at distances of up to 900 mu m from the CE's tip.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 11 条
  • [1] DEPENDENCE OF CORTICAL PLASTICITY ON CORRELATED ACTIVITY OF SINGLE NEURONS AND ON BEHAVIORAL CONTEXT
    AHISSAR, E
    VAADIA, E
    AHISSAR, M
    BERGMAN, H
    ARIELI, A
    ABELES, M
    [J]. SCIENCE, 1992, 257 (5075) : 1412 - 1415
  • [2] ASTONJONES G, 1985, PHYSIOL PSYCHOL, V13, P118
  • [3] A TUNGSTEN-IN-GLASS IONTOPHORESIS ASSEMBLY FOR STUDYING INPUT-OUTPUT RELATIONSHIPS IN CENTRAL NEURONS
    GODWIN, DW
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1993, 49 (03) : 211 - 223
  • [4] A COMBINED RECORDING AND MICROIONTOPHORESIS TECHNIQUE FOR INPUT OUTPUT ANALYSIS OF SINGLE NEURONS IN THE MAMMALIAN CNS
    GOTTSCHALDT, KM
    HICKS, TP
    VAHLEHINZ, C
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1988, 23 (03) : 233 - 239
  • [5] FABRICATION OF A METAL-CORED MULTI-BARRELED MICROIONTOPHORESIS ASSEMBLY
    HELLIER, M
    BOERS, P
    LAMBERT, GA
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1990, 32 (01) : 55 - 61
  • [6] ANOTHER TUNGSTEN MICROELECTRODE
    LEVICK, WR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (04): : 510 - &
  • [7] MULTIBARRELED GLASS-COATED TUNGSTEN MICROELECTRODE FOR BOTH NEURONAL-ACTIVITY RECORDING AND IONTOPHORESIS IN MONKEYS
    LI, BM
    MEI, ZT
    KUBOTA, K
    [J]. NEUROSCIENCE RESEARCH, 1990, 8 (03) : 214 - 219
  • [8] Millar J, 1992, MONITORING NEURONAL, P1
  • [9] A TECHNIQUE FOR MICROIONTOPHORETIC STUDY OF SINGLE NEURONS IN THE BEHAVING MONKEY
    PERRETT, DI
    ROLLS, ET
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1985, 12 (04) : 289 - 295
  • [10] STONE TW, 1985, IBRO HDB SERIES METH, V8