RECENT DEVELOPMENTS IN DXA - QUALITY OF NEW DXA/MXA-DEVICES FOR DENSITOMETRY AND MORPHOMETRY

被引:20
作者
FELSENBERG, D
GOWIN, W
DIESSEL, E
ARMBRUST, S
MEWS, J
机构
[1] Osteoporosis Research Group, Abt. für Radiologische Diagnostik und Nuklearmedizin, Universitätsklinikum Benjamin Franklin
关键词
DUAL X-RAY ABSORPTIOMETRY; MORPHOMETRY X-RAY ABSORPTIOMETRY; OSTEOPOROSIS;
D O I
10.1016/0720-048X(95)00682-G
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of new devices demands the assessment of their capabilities in established terms. The accuracy, reproducibility and spatial resolution of in vitro (phantom) osteodensitometric and morphometric measurements of QDR 2000 Plus and EXPERT are presented. Design details of these DXA/MXA-devices are listed and discussed in combination with the data acquired in the test measurements and calculations. The image quality will improve with further software developments. The long-term reproducibility and in vivo reliability remains to be evaluated.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 20 条
[1]  
Kalender, A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: Design considerations and specifications, Med Phys, 19, (1992)
[2]  
Kalender, Helm, Polacin, Seibetaer, Felsenberg, Ein neues Phantom für die Standardisierung und Qualitätskontrolle von Knochenmineralmessungen mit CT und Photonenabsorptiometrie, Medizinische Physik 91, Deutsche Gesellschaft für Medizinische Physik, pp. 208-209, (1991)
[3]  
Gluer, Faulkner, Estilo, Engelke, Rosin, Genant, Quality assurance for bone densitometry research studies: Concept and Impact, Osteoporosis Int, 3, (1993)
[4]  
Finkelstein, Butler, Cleary, Neer, Comparison of four methods for cross-calibrating dual-energy X-ray absorptiometers to eliminate systematic errors when upgrading equipment, J Bone Min Res, 9, (1994)
[5]  
Hanson, Ergun, Gauntt, Bisek, Mazess, New development in imaging densitometry: Expert-XL, Bone, 16, (1995)
[6]  
Gluer, Faulkner, Powell, Genant, Accuracy of two different dual-energy X-ray absorptiometry systems: Assessment of potential error sources, Radiology, 177 (P, (1990)
[7]  
Blake, Parker, Buxton, Fogelman, Dual X-ray absorptiometry: a comparison between fan beam and pencil beam scans, Br J Radiol, 66, (1993)
[8]  
Eiken, Barenholdt, Bjorn Jensen, Gram, Pors Nielsen, Switching from DXA pencil-beam to Fan-beam. I: Studies in vitro at four centers, Bone, 15, (1994)
[9]  
Steiger, Wahner, Instruments using fan beam geometry, The evaluation of osteoporosis: Dual-energy X-ray absorptiometry in clinical practice, pp. 75-87, (1994)
[10]  
Eiken, Kolthoff, Barenholdt, Hermansen, Pors Nielsen, Switching from DXA pencil-beam to fan-beam. II: Studies in vivo, Bone, 15, (1994)