RECENT DEVELOPMENTS IN DXA - QUALITY OF NEW DXA/MXA-DEVICES FOR DENSITOMETRY AND MORPHOMETRY

被引:20
作者
FELSENBERG, D
GOWIN, W
DIESSEL, E
ARMBRUST, S
MEWS, J
机构
[1] Osteoporosis Research Group, Abt. für Radiologische Diagnostik und Nuklearmedizin, Universitätsklinikum Benjamin Franklin
关键词
DUAL X-RAY ABSORPTIOMETRY; MORPHOMETRY X-RAY ABSORPTIOMETRY; OSTEOPOROSIS;
D O I
10.1016/0720-048X(95)00682-G
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of new devices demands the assessment of their capabilities in established terms. The accuracy, reproducibility and spatial resolution of in vitro (phantom) osteodensitometric and morphometric measurements of QDR 2000 Plus and EXPERT are presented. Design details of these DXA/MXA-devices are listed and discussed in combination with the data acquired in the test measurements and calculations. The image quality will improve with further software developments. The long-term reproducibility and in vivo reliability remains to be evaluated.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 20 条
[11]  
Gundry, Miller, Ramos, Moscona, Stein, Mazess, Sartoris, Resnick, Dual-energy radiographic absorptiometry of the lumbar spine: Clinical experience with two different systems, Radiology, 174, (1990)
[12]  
Faulkner, Gluer, Estilo, Genant, Crosscalibration of DXA equipment: Upgrading from Hologic QDR 1000/W to a QDR 2000, Calcif Tissue Int, 52, (1993)
[13]  
Faulkner, Genant, McClung, Bilateral comparison of femoral bone density and hip axis length from single and fan beam DXA scans, Calcif Tissue Int, 56, (1995)
[14]  
Fuleihan, Testa, Angell, Porrino, Leboff, Reproducibility of DXA absorptiometry: a model for bone loss estimates, J Bone Min Res, 10, (1995)
[15]  
Devogelaer, Baudoux, Nagant de Deuxchaisnes, Reproducibility of BMD measurements on the QDR 2000, Calcif Tissue Int, 52, (1993)
[16]  
Engelke, Gluer, Genant, Factors influencing short term precision of dual X-ray bone absorptiometry (DXA) of spine and femur, Calcif Tissue Int, 56, (1995)
[17]  
Assessing vertebral fractures, J Bone Min Res, 10, (1995)
[18]  
Steiger, Cummings, Genant, Weiss, Morphometric X-ray absorptiometry of the spine: Correlation in vivo with morphometric radiography, Osteoporosis Int, 4, (1994)
[19]  
Steiger, Ettinger, Weiss, von Stetten, Stein, Reproducibility of morphometric X-ray absorptiometry for the determination of vertebral deformities, J Bone Min Res, 8, (1993)
[20]  
Hans, Duboeuf, Schott, Sornay Rendu, Liens, Delmas, Meunier, Clinical evaluation of a new vertebral morphometric technique to estimate osteoporotic vertebral fracture, Bone, 16, (1995)