INFLUENCE OF THIGH MUSCLES ON THE AXIAL STRAINS IN A PROXIMAL FEMUR DURING EARLY STANCE IN GAIT

被引:82
作者
CRISTOFOLINI, L
VICECONTI, M
TONI, A
GIUNTI, A
机构
[1] Biomaterials Technology Laboratory, Rizzoli Orthopaedic Institute, 40136 Bologna
关键词
D O I
10.1016/0021-9290(94)00106-E
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This work is focused on the in vitro simulation of the loads occurring in the femur during early stance in gait, for hip prostheses stress shielding test purposes. Ten thigh muscles (the three gluteal muscles, the three vasti, rectus femoris, adductor longus and magnus, biceps femoris), simulated by nylon straps, were tested in order to establish their influence on the strains in the proximal femur. Axial and hoop strains were recorded from 16 strain gauges for the effect of each muscle and compared to the strains recorded as a result of the hip joint reaction force only (i.e. without muscle simulation). It appears that the three glutei are the principal muscles in determining the vertical strains, however the rectus femoris, biceps femoris and the adductors were also seen to significantly affect the strain pattern. The inadequacy of increasing the adduction angle and applying the resultant force at the hip joint to simulate the abductors was also confirmed.
引用
收藏
页码:617 / 624
页数:8
相关论文
共 42 条
[1]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[2]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[3]   ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
CHEAL, EJ ;
SPECTOR, M ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) :405-422
[4]  
Crick D, 1985, Acta Orthop Belg, V51, P168
[5]   ANALYSIS OF FEMORAL COMPONENT STEM DESIGN IN TOTAL HIP-ARTHROPLASTY [J].
CROWNINSHIELD, RD ;
BRAND, RA ;
JOHNSTON, RC ;
MILROY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (01) :68-78
[6]   BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85
[7]   A MEASUREMENT OF PROXIMAL FEMUR STRAIN WITH TOTAL HIP-ARTHROPLASTY [J].
CROWNINSHIELD, RD ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (03) :230-233
[8]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[9]  
Delecrin J, 1989, Acta Orthop Belg, V55, P150
[10]  
Diegel P D, 1989, J Arthroplasty, V4, P173, DOI 10.1016/S0883-5403(89)80071-3