AN ONLINE IMMUNOASSAY METHOD FOR THEOPHYLLINE USING A PROTEIN-A IMMUNOREACTOR

被引:8
作者
FERNANDEZHERNANDO, P [1 ]
MILLER, JN [1 ]
机构
[1] LOUGHBOROUGH UNIV TECHNOL,DEPT CHEM,LOUGHBOROUGH LE11 3TU,LEICS,ENGLAND
关键词
THEOPHYLLINE; FLOW INJECTION ANALYSIS; HETEROGENEOUS FLUORESCENCE IMMUNOASSAY; PROTEIN-A REACTOR;
D O I
10.1016/0731-7085(91)80053-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A heterogeneous fluorescence immunoassay for theophylline has been automated using a flow injection analysis system containing a protein A solid phase reactor to separate antibody-bound and unbound fluorescein-theophylline. For each sample the antibody-protein A reaction takes place at near neutral pH, and the complexes are eluted at acid pH. The antibody-binding capacity of the reaction greatly exceeds the antibody level in each sample incubation mixture, and a single reactor can be repeatedly cycled between neutral and acid pHs. Experimental variations such as reactor size, flow rate, pH values, and reactant concentrations have been studied. Theophylline could readily be determined at the mu-g ml-1 level with on-line incubation with antibodies.
引用
收藏
页码:1121 / 1123
页数:3
相关论文
共 12 条
[1]   HOMOGENEOUS FLUOROIMMUNOASSAY USING LUCIFER YELLOW VS - DETERMINATION OF ALBUMIN PLASMA [J].
BAILEY, MP ;
ROCKS, BF ;
RILEY, C .
ANNALS OF CLINICAL BIOCHEMISTRY, 1984, 21 (JAN) :59-63
[2]   RAPID HETEROGENEOUS COMPETITIVE ELECTROCHEMICAL IMMUNOASSAY FOR IGG IN THE PICOMOLE RANGE [J].
DEALWIS, U ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2786-2789
[3]  
DEALWIS WU, 1985, ANAL CHEM, V57, P2754
[4]   FLOW-INJECTION ANALYSIS FOR GLUCOSE AND UREA WITH ENZYME REACTORS AND ONLINE DIALYSIS [J].
GORTON, L ;
OGREN, L .
ANALYTICA CHIMICA ACTA, 1981, 130 (01) :45-53
[5]  
HUGHES A, 1985, Analytical Proceedings, V22, P16
[6]   DUAL-COLUMN IMMUNOASSAYS USING PROTEIN-G AFFINITY-CHROMATOGRAPHY [J].
JANIS, LJ ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1901-1906
[7]   HOMOGENEOUS ENZYMATIC FLUORESCENCE IMMUNOASSAY OF SERUM IGG BY CONTINUOUS FLOW-INJECTION ANALYSIS [J].
KELLY, TA ;
CHRISTIAN, GD .
TALANTA, 1982, 29 (12) :1109-1112
[8]   AUTOMATION OF AN ENERGY-TRANSFER IMMUNOASSAY BY USING STOPPED-FLOW INJECTION-ANALYSIS WITH MERGING ZONES [J].
LIM, CS ;
MILLER, JN ;
BRIDGES, JW .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :183-189
[9]   LIPOSOME FLOW-INJECTION IMMUNOASSAY - IMPLICATIONS FOR SENSITIVITY, DYNAMIC-RANGE, AND ANTIBODY REGENERATION [J].
LOCASCIOBROWN, L ;
PLANT, AL ;
HORVATH, V ;
DURST, RA .
ANALYTICAL CHEMISTRY, 1990, 62 (23) :2587-2593
[10]   STUDIES OF INTERACTING BIOCHEMICAL SYSTEMS BY FLOW-INJECTION ANALYSIS [J].
MILLER, JN ;
ABDULLAHI, GL ;
STURLEY, HN ;
GOSSAIN, V ;
MCCLUSKEY, PL .
ANALYTICA CHIMICA ACTA, 1986, 179 :81-90