AMPEROMETRIC GLUCOSE-SENSING ELECTRODE BASED ON CARBON-PASTE CONTAINING POLY(ETHYLENE GLYCOL)-MODIFIED GLUCOSE-OXIDASE AND COBALT OCTAETHOXYPHTHALOCYANINE

被引:45
作者
MIZUTANI, F
YABUKI, S
IIJIMA, S
机构
[1] National Institute of Bioscience and Human-Technology, Tsukuba, Ibaraki, 305
关键词
AMPEROMETRY; GLUCOSE; ENZYME ELECTRODE; OCTAETHOXYPHTHALOCYANINE;
D O I
10.1016/0003-2670(94)00403-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode for glucose was prepared by incorporating poly (ethylene glycol)-modified glucose oxidase and cobalt octaethoxyphthalocyanine [CoPc(OEt)(8)], a new mediator, into a carbon paste matrix. The polymer-modified enzyme exhibited a higher activity than the native enzyme in the hydrophobic carbon paste medium. CoPc(OEt)(8) could oxidize the enzyme at more negative potentials than unsubstituted cobalt phthalocyanine (CoPc). Further, the CoPc(OEt)(8)-mediated enzyme electrode showed a high stability: the electrode response to glucose did not decrease for at least 4 weeks (or for 700 assays), whereas the glucose response from a CoPc-mediated enzyme electrode fell to half of the initial value within 2 weeks (or after 300 assays). CoPc(OEt)(8), a paraffin-oil soluble derivative of CoPc, incorporated in the bulk of carbon paste, diffused towards the electrode surface so as to renew continuously the electrode surface, which resulted in the high stability of the new mediator-based enzyme electrode.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 37 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[2]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[3]   AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ .
TALANTA, 1991, 38 (01) :107-110
[4]   MICRO METHOD FOR MANUAL ANALYSIS OF TRUE GLUCOSE IN PLASMA WITHOUT DEPROTEINIZATION [J].
BAUMINGER, BB .
JOURNAL OF CLINICAL PATHOLOGY, 1974, 27 (12) :1015-1017
[5]   POLYMER-FILMS ON ELECTRODES .13. INCORPORATION OF CATALYSTS INTO ELECTRONICALLY CONDUCTIVE POLYMERS - IRON PHTHALOCYANINE IN POLYPYRROLE [J].
BULL, RA ;
FAN, FR ;
BARD, AJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1984, 131 (03) :687-690
[6]  
Cardosi M. F., 1991, ADV BIOSENSORS, V1, P125
[7]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[8]   POTENTIALLY-IMPLANTABLE, FERROCENE-MEDIATED GLUCOSE SENSOR [J].
CLAREMONT, DJ ;
PENTON, C ;
PICKUP, JC .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (03) :272-274
[9]   QUINOPROTEIN GLUCOSE-DEHYDROGENASE AND ITS APPLICATION IN AN AMPEROMETRIC GLUCOSE SENSOR [J].
DCOSTA, EJ ;
HIGGINS, IJ ;
TURNER, APF .
BIOSENSORS, 1986, 2 (02) :71-87
[10]  
DICKS JM, 1989, ANN BIOL CLIN-PARIS, V47, P607