MR TOMOGRAPHY WITH FAST-SPIN-ECHO SEQUENCES - RESULTS IN THE ENT REGION

被引:4
作者
BRUNING, R
NAEGELE, M
HEUK, A
SEELOS, K
KUNZE, V
SCHNAKENBERG, D
REISER, M
机构
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1993年 / 158卷 / 05期
关键词
MRI; T2-SPIN-ECHO; HEAD AND NECK; FAST IMAGING;
D O I
10.1055/s-2008-1032680
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of T2-weighted spin-echo sequences is mandatory for identifying tumours in the ENT region and for differential diagnosis of pathological findings. A highly promising alternative to time-consuming conventional SE sequences is now available in the fast-spin-echo sequences (FSE). FSE was compared with the conventional SE (CSE) basing on 100 assessments of examinations of 20 patients. Results: Conventional SE = TR/TE = 1800/90 ms with one average (NEX), FSE = TR/TE = 3200/120 ms with 4 averages (NEX). Measurement time CSE 6:59 min, FSE 3:12 min. Analysis was performed in analogy to on ROC analysis by 5 radiologists as a blind study. The anatomic differentiation and contrast performance were compared as well as the differentiation and definition of lesion and lymphatic node and a subjective overall assessment. Differentiation of pathological findings was the same with both sequences. FSE was superior to CSE in the visualisation of normal tissue, lymph nodes and also in the subjective overall assessment. The following criteria were employed in the subjective overall valuation: sum total of impressions gathered from contrast behaviour or performance, susceptibility to artifacts, and signal-to-noise ratio. Due to the definitely improved parameters of image quality and the markedly reduced scanning time - which is reduced to 50% - FSE will replace the conventional spin-echo sequence in routine diagnostics.
引用
收藏
页码:445 / 450
页数:6
相关论文
共 17 条
[1]  
BONGARTZ G, 1992, ZBL RADIOL, V146, P21
[2]  
BONGARTZ G, 1992, ZBL RADIOL, V146, P1
[3]   SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[4]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[5]   MR-IMAGING WITH GD-DTPA IN CARCINOMAS OF TONGUE, OROPHARYNX AND HYPOPHARYNX [J].
EINSPIELER, R ;
EBNER, F ;
POSAWETZ, W ;
RANNER, G ;
FLUCKIGER, F ;
LAMMER, J .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 13 (01) :21-26
[6]  
HAAKE EM, 1986, RADIOLOGY, V158, P521
[7]   NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS [J].
HAYES, CE ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :181-191
[8]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[9]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[10]  
KREFT B, 1992, MED MUNDI, V36, P152