IMPROVED PRECISION IN A RESONANCE IONIZATION MASS-SPECTROMETER BY THE USE OF STARK-SHIFTED SPECTRAL-LINES AS A PROBE FOR EXTRACTION FIELD

被引:2
作者
DOWNEY, SW
EMERSON, AB
FULLOWAN, TR
机构
[1] AT and T Bell Laboratories, Murray Hill, NJ 07074
关键词
STARK EFFECT; FIELD IONIZATION; RESONANCE IONIZATION; DEPTH PROFILING; GAAS;
D O I
10.1366/0003702934067883
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-lying (Rydberg) electronic levels of sputtered Na atoms are spectrally shifted by the strong ion extracting electric field (greater-than-or-equal-to 12 kV/cm) present in a resonance ionization mass spectrometer (Stark effect). The Stark-shifted lines are a beneficial diagnostic to probe the ion source's local electric field, which is related to sample alignment and hence ion transmission efficiency. Changes in electric field of 1% can be detected spectrally, so the sample position is controlled to less-than-or-equal-to 10 mum by this technique. Results show that by the use of the Na spectrum as an alignment aid prior to sputter depth profiling, the precision of the RIMS instrument, as measured by the reproducibility of either the peak of the integrated signals from Be-implanted GaAs, is improved to about +/-3%-at least a fourfold improvement over the best previous results. Spatial variations in the Be-ion implant dose over a GaAs wafer may be detected because of improved precision.
引用
收藏
页码:1245 / 1250
页数:6
相关论文
共 13 条
[1]   ELECTRIC FIELD IONIZATION PROBABILITIES FOR HYDROGEN ATOM [J].
BAILEY, DS ;
HISKES, JR ;
RIVIERE, AC .
NUCLEAR FUSION, 1965, 5 (01) :41-&
[2]  
Bethe H. A., 1957, QUANTUM MECH ONEAND, DOI DOI 10.1007/978-3-662-12869-5
[3]   PRECISION STARK SPECTROSCOPY OF SODIUM - IMPROVED VALUES FOR THE IONIZATION LIMIT AND BOUND-STATES [J].
CIOCCA, M ;
BURKHARDT, CE ;
LEVENTHAL, JJ ;
BERGEMAN, T .
PHYSICAL REVIEW A, 1992, 45 (07) :4720-4730
[4]  
Condon E.U., 1963, THEORY ATOMIC SPECTR
[5]   A HYBRID-RESONANCE IONIZATION AND SECONDARY IONIZATION MASS-SPECTROMETER [J].
DOWNEY, SW ;
HOZACK, RS .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (02) :791-796
[6]   QUANTITATIVE DEPTH PROFILING RESONANCE IONIZATION MASS-SPECTROMETRY OF SEMICONDUCTORS WITH MINIMUM STANDARDIZATION [J].
DOWNEY, SW ;
EMERSON, AB .
ANALYTICAL CHEMISTRY, 1991, 63 (09) :916-918
[7]  
KLEPPNER D, 1983, RYDBERG STATES ATOMS, P73
[8]   TUNNELING RATES FOR EXCITED-STATES OF SODIUM IN A STATIC ELECTRIC-FIELD [J].
LITTMAN, MG ;
ZIMMERMAN, ML ;
KLEPPNER, D .
PHYSICAL REVIEW LETTERS, 1976, 37 (08) :486-489
[9]  
Moore C.E., 1949, US NAT BUR STAND PUB, V467, p24Cr
[10]  
SIMONTON RB, 1992, SOLID STATE TECHNOL, P29