A Classification System to Detect Congestive Heart Failure Using Second-Order Difference Plot of RR Intervals

被引:39
作者
Thuraisingham, R. A.
机构
关键词
D O I
10.4061/2009/807379
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
A classification system to detect congestive heart failure (CHF) patients from normal (N) patients is described. The classification procedure uses the k-nearest neighbor algorithm and uses features from the second-order difference plot (SODP) obtained from Holter monitor cardiac RR intervals. The classification system which employs a statistical procedure to obtain the final result gave a success rate of 100% to distinguish CHF patients from normal patients. For this study the Holter monitor data of 36 normal and 36 CHF patients were used. The classification system using standard deviation of RR intervals also performed well, although it did not match the 100% success rate using the features from SODP. However, the success rate for classification using this procedure for SDRR was many fold higher compared to using a threshold. The classification system in this paper will be a valuable asset to the clinician, in the detection congestive heart failure. Copyright (C) 2009 R. A. Thuraisingham.
引用
收藏
页数:7
相关论文
共 16 条
[1]
Automatic identification of cardiac health using modeling techniques: A comparative study [J].
Acharya, U. Rajendra ;
Sankaranarayanan, Meena ;
Nayak, Jagadish ;
Xiang, Chen ;
Tamura, Toshiyo .
INFORMATION SCIENCES, 2008, 178 (23) :4571-4582
[2]
Lifelink: 3G-Based Mobile Telemedicine System [J].
Alis, Christian ;
del Rosario, Carlos ;
Buenaobra, Bernardino ;
Blanca, Carlo Mar .
TELEMEDICINE JOURNAL AND E-HEALTH, 2009, 15 (03) :241-247
[3]
Measures of heart period variability as predictors of mortality in hospitalized patients with decompensated congestive heart failure [J].
Aronson, D ;
Mittleman, MA ;
Burger, AJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (01) :59-63
[4]
Berikov V., 2003, METHODS STAT DATA AN
[5]
Do existing measures of Poincare plot geometry reflect nonlinear features of heart rate variability? [J].
Brennan, M ;
Palaniswami, M ;
Kamen, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (11) :1342-1347
[6]
Applying continuous chaotic modeling to cardiac signal analysis [J].
Cohen, ME ;
Hudson, DL ;
Deedwania, PC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (05) :97-102
[7]
ROBUST ESTIMATES, RESIDUALS, AND OUTLIER DETECTION WITH MULTIRESPONSE DATA [J].
GNANADESIKAN, R ;
KETTENRING, JR .
BIOMETRICS, 1972, 28 (01) :81-+
[8]
PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[9]
Gunn S. R., 1997, TECH REP
[10]
Prognosis in heart failure with preserved left ventricular systolic function: prospective cohort study [J].
MacCarthy, PA ;
Kearney, MT ;
Nolan, J ;
Lee, AJ ;
Prescott, RJ ;
Shah, AM ;
Brooksby, WP ;
Fox, KAA .
BRITISH MEDICAL JOURNAL, 2003, 327 (7406) :78-79