MR-IMAGING OF REGIONAL CARDIAC-FUNCTION - LOW-PASS FILTERING OF WALL THICKNESS CURVES

被引:9
作者
LAMB, HJ
SINGLETON, RR
VANDERGEEST, RJ
POHOST, GM
DEROOS, A
机构
[1] UNIV ALABAMA,DEPT CARDIOVASC DIS,BIRMINGHAM,AL
[2] UNIV LEIDEN HOSP,CLIN & EXPTL IMAGE PROC LAB,LEIDEN,NETHERLANDS
关键词
REGIONAL CARDIAC FUNCTION; DIASTOLIC FUNCTION; LOWPASS FILTER; TEMPORAL FILTERING;
D O I
10.1002/mrm.1910340332
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Wall thickness curves (WTCs) derived from MR images are subject to considerable measurement error, This study determines the effects of low-pass Fourier filtering of WTCs on functional parameters derived from the curve: peak rate of wall thinning (PRWT) and time to PRWT (TPRWT), The intersubject standard deviation (SD) of PRWT changed from 0.35 to 0.18, and the SD of TPRWT from 34.3 to 29.5. Differences between neighboring segments decreased from 0.31 to 0.15% mean thickness/ms for PRWT (P = 0.012), and from 35.0 to 19.0 ms for TPRWT (P = 0.005), It is concluded that filtering of MR imaging-derived WTCs contributes to a better representation of myocardial wall motion.
引用
收藏
页码:498 / 502
页数:5
相关论文
共 23 条
  • [1] BACHARACH SL, 1984, INFORMATION PROCESSI, P266
  • [2] BONOW RO, 1991, CIRCULATION S1, V84, P208
  • [3] THE EFFECT OF AVERAGING CARDIAC DOPPLER SPECTROGRAMS ON THE REDUCTION OF THEIR AMPLITUDE VARIABILITY
    CLOUTIER, G
    ALLARD, L
    GUO, Z
    DURAND, LG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (02) : 177 - 186
  • [4] REAL-TIME MOVIE IMAGE-ENHANCEMENT IN NMR
    DOYLE, M
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1986, 19 (06): : 439 - 444
  • [5] TOTAL EXCITATION OF ISOLATED HUMAN HEART
    DURRER, D
    VANDAM, RT
    FREUD, GE
    JANSE, MJ
    MEIJLER, FL
    ARZBAECHER, RC
    [J]. CIRCULATION, 1970, 41 (06) : 899 - +
  • [6] ALIGNMENT METHODS FOR AVERAGING OF HIGH-RESOLUTION CARDIAC SIGNALS - A COMPARATIVE-STUDY OF PERFORMANCE
    JANE, R
    RIX, H
    CAMINAL, P
    LAGUNA, P
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (06) : 571 - 579
  • [7] ESTIMATION OF HUMAN MYOCARDIAL MASS WITH MR IMAGING
    KATZ, J
    MILLIKEN, MC
    STRAYGUNDERSEN, J
    BUJA, LM
    PARKEY, RW
    MITCHELL, JH
    PESHOCK, RM
    [J]. RADIOLOGY, 1988, 169 (02) : 495 - 498
  • [8] THE VALUE OF CINE NUCLEAR MAGNETIC-RESONANCE IMAGING FOR ASSESSING REGIONAL VENTRICULAR-FUNCTION
    LOTAN, CS
    CRANNEY, GB
    BOUCHARD, A
    BITTNER, V
    POHOST, GM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (07) : 1721 - 1729
  • [9] EVALUATION OF LEFT-VENTRICULAR VOLUMES MEASURED BY MAGNETIC-RESONANCE-IMAGING
    MOGELVANG, J
    THOMSEN, C
    MEHLSEN, J
    BRACKLE, G
    STUBGAARD, M
    HENRIKSEN, O
    [J]. EUROPEAN HEART JOURNAL, 1986, 7 (12) : 1016 - 1021
  • [10] ABNORMAL EXERCISE HEMODYNAMICS IN PATIENTS WITH NORMAL SYSTOLIC FUNCTION LATE AFTER AORTIC-VALVE REPLACEMENT
    MONRAD, ES
    HESS, OM
    MURAKAMI, T
    NONOGI, H
    CORIN, WJ
    KRAYENBUEHL, HP
    [J]. CIRCULATION, 1988, 77 (03) : 613 - 624