SIGNAL ENHANCEMENT AND REDUCTION OF INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH AN ARGON-TRIFLUOROMETHANE MIXED AEROSOL CARRIER GAS

被引:15
作者
PLATZNER, I [1 ]
SALA, JV [1 ]
MOUSTY, F [1 ]
TRINCHERINI, PR [1 ]
POLETTINI, AL [1 ]
机构
[1] JOINT RES CTR,SEA,MARCONI TECHNOL,TP 460,I-21020 ISPRA,ITALY
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; TRIFLUOROMETHANE ADDITION; INTERFERENCE REDUCTION; ANALYTE SIGNAL ENHANCEMENT; DETECTION LIMITS;
D O I
10.1039/ja9940900719
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The addition of trifluoromethane (CHF3) to the aerosol carrier gas in inductively coupled plasma mass spectrometry was assessed as a method of improving detection limits (DL) for elements such as As, Se, Cu and Zn in matrices containing interfering species. It was observed that in each case the analyte response was significantly increased with a coincident decrease in the blank signal. The improved DL for As in Cl- and Ca2+ matrices (interference (ArCl+)-Ar-39-Cl-35 and (CaO2+)-Ca-43-O-16 were 0.02 and 0.04 ng ml-1 compared with 0.65 and 0.28 ng ml-1, respectively, without CHF3; for Se-78 (interference (ArAr+)-Ar-40-Ar-38 0.032 compared with 0.88 ng ml-1; for Cu-63 in Na2SO4 or Na2HPO4 matrices (interferences (ArNa+)-Ar-40-Na-23 and (PO2+)-P-31-O-16 0.022 and 0.089 compared with 0.35 and 0.53 ng ml-1, respectively; and for Zn-64 in an Na2HPO2 matrix (interferences (HPO2+)-P-31-O-16 and (POO+)-P-31-O-16-O-17 0.011 compared with 0.42 ng ml-1. The reduction of the interference is attributed to competitive reactions between the matrix species and the CHF3 or species derived from it in the plasma. The analyte enhancement effect is not yet clear. It has been suggested that this effect is related to elements with ionization potential (IP) in the 9-11 eV region and is affected by organic compounds added to the aerosol carrier gas stream. Copper (IP 7.73 eV), Al (5.99 eV), Br (11.30 ev) and I (10.44 ev) are exceptions to this assumption. Analytical curves of the studied elements at low ppb and sub-ppb levels (in the interfering matrices) further demonstrated the advantage of adding CHF3 in trace elemental analysis.
引用
收藏
页码:719 / 726
页数:8
相关论文
共 22 条
[1]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[2]   DETERMINATION OF ARSENIC BY HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING A TUBULAR MEMBRANE GAS-LIQUID SEPARATOR [J].
BRANCH, S ;
CORNS, WT ;
EBDON, L ;
HILL, S ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :155-158
[3]   DETERMINATION OF ARSENIC IN SAMPLES WITH HIGH CHLORIDE CONTENT BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BRANCH, S ;
EBDON, L ;
FORD, M ;
FOULKES, M ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :151-154
[4]   DETERMINATION OF SELENIUM BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY UTILIZING A NEW HYDRIDE GENERATION SAMPLE INTRODUCTION SYSTEM [J].
BUCKLEY, WT ;
BUDAC, JJ ;
GODFREY, DV ;
KOENIG, KM .
ANALYTICAL CHEMISTRY, 1992, 64 (07) :724-729
[5]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .7. ANALYSIS OF COAL USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EBDON, L ;
FOULKES, ME ;
PARRY, HGM ;
TYE, CT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :753-761
[6]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[7]   MINIMIZATION OF INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING ONLINE PRECONCENTRATION [J].
HEITHMAR, EM ;
HINNERS, TA ;
ROWAN, JT ;
RIVIELLO, JM .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :857-864
[8]   SPECIATION OF ARSENIC IN URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
HEITKEMPER, D ;
CREED, J ;
CARUSO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :279-284
[9]   INVESTIGATIONS INTO THE APPLICATION OF METHANE ADDITION TO THE NEBULIZER GAS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR THE REMOVAL OF POLYATOMIC INTERFERENCES [J].
HILL, SJ ;
FORD, MJ ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) :1157-1165
[10]   A COMPARISON OF ARGON AND MIXED GAS PLASMAS FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
LAM, JWH ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (12) :1313-1325