USE OF DIRECT INJECTION PRECOLUMN TECHNIQUES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE RETINOIDS ACITRETIN AND 13-CIS-ACITRETIN IN PLASMA

被引:23
作者
WYSS, R
BUCHELI, F
机构
[1] Pharma Division, Preclinical Research, F. Hoffmann-La Roche Ltd, CH-4002 Basle
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 593卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80266-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A previously developed highly sensitive high-performance liquid chromatographic method for the determination of retinoids, using direct injection of large plasma volumes, on-line solid-phase extraction and ultraviolet detection, was improved and fully validated for the determination of acitretin and 13-cis-acitretin in plasma samples. The addition of acetonitrile to improve the recovery was performed on-line by a T-piece, avoiding any cis-trans isomerization which could occur when acetonitrile was added prior to storage in the autosampler. About 30 injections could be made onto one precolumn despite the large injection volume (1 ml of plasma containing the internal standard). Full automation was attained by the use of automated precolumn replacement. In addition, forward- and back-flush purging of the precolumn enhanced the longevity of the analytical column. This consisted of three coupled C-18 columns of 125 mm length each. The quantification limit was 0.3 ng/ml, using ultraviolet detection at 360 nm, and the mean inter-assay precision was 3.8% for the two compounds.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 19 条
[1]  
BOLLAG W, 1985, RETINOIDS NEW TRENDS, P274
[2]   OVERVIEW OF RECENT CLINICAL PHARMACOKINETIC STUDIES WITH ACITRETIN (RO 10-1670, ETRETIN) [J].
BRINDLEY, CJ .
DERMATOLOGICA, 1989, 178 (02) :79-87
[3]  
CHOU RC, IN PRESS LIFE SCI
[4]  
ECKHOFF C, 1990, J LIPID RES, V31, P1445
[5]   QUANTIFICATION OF ACITRETIN IN HUMAN PLASMA BY MICROBORE LIQUID-CHROMATOGRAPHY NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
FAYER, BE ;
HUSELTON, CA ;
GARLAND, WA ;
LIBERATO, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01) :135-144
[6]   A ROAD LESS TRAVELED - NORMAL PHASE MICROBORE LIQUID-CHROMATOGRAPHY - MASS-SPECTROMETRY USING DIRECT LIQUID INTRODUCTION [J].
GARLAND, WA ;
HUSELTON, CA ;
KOLINSKY, F ;
LIBERATO, DJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (06) :177-184
[7]   ACITRETIN (RO 10-1670, ETRETIN) - OVERALL EVALUATION OF CLINICAL-STUDIES [J].
GEIGER, JM ;
CZARNETZKI, BM .
DERMATOLOGICA, 1988, 176 (04) :182-190
[8]   GLUTATHIONE CATALYSIS OF INTERCONVERSION OF ACITRETIN AND ITS 13-CIS ISOMER ISOACITRETIN [J].
JEWELL, RC ;
MCNAMARA, PJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (05) :444-446
[9]   AUTOMATED-DETERMINATION OF 13-CIS-TRANS-RETINOIC AND ALL-TRANS-RETINOIC ACID, THEIR 4-OXO METABOLITES AND RETINOL IN PLASMA, AMNIOTIC-FLUID AND EMBRYO BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A PRECOLUMN SWITCHING TECHNIQUE [J].
KRAFT, JC ;
ECHOFF, C ;
KUHNZ, W ;
LOFBERG, B ;
NAU, H .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (9-10) :2051-2069
[10]   TERATOGENICITY OF THE 13-CIS AND ALL-TRANS-ISOMERS OF THE AROMATIC RETINOID ETRETIN - CORRELATION TO TRANSPLACENTAL PHARMACOKINETICS IN MICE DURING ORGANOGENESIS AFTER A SINGLE ORAL DOSE [J].
LOFBERG, B ;
CHAHOUD, I ;
BOCHERT, G ;
NAU, H .