CARDIAC DOPPLER BLOOD-FLOW SIGNAL ANALYSIS .2. TIME-FREQUENCY REPRESENTATION BASED ON AUTOREGRESSIVE MODELING

被引:15
作者
GUO, Z
DURAND, LG
ALLARD, L
CLOUTIER, G
LEE, HC
LANGLOIS, YE
机构
[1] MCGILL UNIV, DEPT ELECT ENGN, 3480 UNIV ST, MONTREAL H3A 2A7, QUEBEC, CANADA
[2] HOTEL DIEU MONTREAL HOSP, NONINVAS CARDIOVASC RES LAB, MONTREAL H2W 1T5, PQ, CANADA
关键词
AUTOREGRESSIVE MODELING; DOPPLER SPECTROGRAM; MODELING ERRORS; MODEL ORDER; WINDOW DURATION;
D O I
10.1007/BF02458043
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Doppler spectrograms obtained by using autoregressive (AR) modelling based on the Yule-Walker equations were investigated, A complex AR model using the in-phase and the quadrature components of the Doppler signal was used to provide blood-flow directions. The effect of model orders on the spectrogram estimation was studied using cardiac Doppler blood flow signals taken from 20 patients. The 'final prediction error' (FPE) and the Akaike's information criterion' (AIC) provided almost identical results in model-order selection. An index, the spectral envelope area (SEA), was used to evaluate the effect of window duration and sampling frequency on AR Doppler spectrogram estimation. The statistical analysis revealed that the SEA obtained from AR modelling was not sensitive to window duration and sampling frequency. This result verified the consistency of the AR Doppler spectrogram. The white-noise characteristics of the AR modelling error signal indicated that the Doppler blood-flow signal can be adequately modelled as a complex AR process. With appropriate model orders, AR modelling provided better Doppler spectrogram estimates than the periodogram.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 20 条
[1]  
Box G.E.P., 1976, TIME SERIES ANAL
[2]   DIGITAL FOURIER TECHNIQUES IN THE DIAGNOSIS AND QUANTIFICATION OF AORTIC-STENOSIS WITH PULSED-DOPPLER ECHOCARDIOGRAPHY [J].
CANNON, SR ;
RICHARDS, KL ;
ROLLWITZ, WT .
JOURNAL OF CLINICAL ULTRASOUND, 1982, 10 (03) :101-107
[3]   COMPUTER EVALUATION OF DOPPLER SPECTRAL ENVELOPE AREA IN PATIENTS HAVING A VALVULAR AORTIC-STENOSIS [J].
CLOUTIER, G ;
LEMIRE, F ;
DURAND, LG ;
LATOUR, Y ;
LANGLOIS, YE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) :247-260
[4]   THE EFFECT OF AVERAGING CARDIAC DOPPLER SPECTROGRAMS ON THE REDUCTION OF THEIR AMPLITUDE VARIABILITY [J].
CLOUTIER, G ;
ALLARD, L ;
GUO, Z ;
DURAND, LG .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (02) :177-186
[5]  
GIDDENS DP, 1985, NONINVASIVE DIAGNOST, P58
[6]  
GUO Z, 1993, CARDIAC DOPPLER BLOO, V31
[7]  
HERMENT A, 1990, 12TH ANN C IEEE EMBS, P310