LIQUID-CHROMATOGRAPHY SOLVENT OPTIMIZATION - POTENTIAL PITFALLS WHEN USING A BLACK-BOX FOR DEVELOPING A QUALITY SEPARATION

被引:5
作者
BOWMAN, PB
HANN, JT
MARR, JGD
SALVAT, DJ
THOMPSON, BE
机构
[1] UPJOHN CO,CONTROL DEV,KALAMAZOO,MI 49001
[2] UNICAM ANALYT SYST,CAMBRIDGE CB1 2PX,ENGLAND
关键词
REVERSED-PHASE LIQUID CHROMATOGRAPHY; SOLVENT OPTIMIZATION; SAMPLE STABILITY; AUTOMATION; CHROMATOGRAPHIC PEAK DECONVOLUTION; CHROMATOGRAPHIC PEAK TRACKING; SPECTRAL LIBRARY;
D O I
10.1016/0731-7085(93)80116-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ICOS and DIAMOND are two commercially available, semi-automated HPLC solvent optimization software packages. The resultant optimized chromatographic separation is dependent on a combination of the operator's objective, the capability of the software system and the appropriateness of the data input. The latter contains components that represent the match between the requirements of the algorithms used and the information content of the data on which those algorithms operated. Knowledge about the sample content, stability and potential sample-solvent interactions can have a significant effect on the quality of the optimal solvent composition that is calculated. The results generated during the optimization of the separation of a mixture of U-83,757 and a variety of related compounds illustrate the need to consider the significance of the contribution to the calculated optimal separation of each of these potential pitfalls, both individually and in combination with the mode of operation of the relevant algorithms. Our results indicate that the quality of the final result is highly dependent on the intelligence content of the data used.
引用
收藏
页码:1295 / 1301
页数:7
相关论文
共 10 条
[1]   DETERMINATION OF CISPLATIN AND RELATED PLATINUM COMPLEXES IN PLASMA ULTRAFILTRATE AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE RADIOACTIVITY DETECTION [J].
BALDEW, GS ;
VOLKERS, KJ ;
DEGOEIJ, JJM ;
VERMEULEN, NPE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (01) :163-174
[2]   AUTOMATED HPLC OPTIMIZATION - NOT ALL SYSTEMS ARE THE SAME [J].
BOWMAN, PB ;
MARR, JGD ;
SALVAT, DJ ;
THOMPSON, BE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1303-1315
[3]  
DROUEN A, 1991, LC GC-MAG SEP SCI, V9, P714
[4]  
DROUEN ACJ, 1982, CHROMATOGRAPHIA, V10, P48
[5]  
FAULSTICH R, 1991, LC GC-MAG SEP SCI, V9, P776
[6]   STUDIES ON THE STABILITY OF CORTICOSTEROIDS .5. THE DEGRADATION PATTERN OF HYDROCORTISONE IN AQUEOUS-SOLUTION [J].
HANSEN, J ;
BUNDGAARD, H .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1980, 6 (3-4) :307-319
[7]  
LYNCH R, 1990, LAB PRACT, V39, P61
[8]   EVALUATION OF A COMPLETE HPLC SOLVENT OPTIMIZATION SYSTEM INVOLVING PIECE-WISE QUADRATIC MODELING [J].
NAISHCHAMBERLAIN, PJ ;
LYNCH, RJ .
CHROMATOGRAPHIA, 1990, 29 (1-2) :79-89
[9]  
PATTERSON SD, 1990, LCGC INT, V9, P54
[10]  
OPTIMISATION SOFTWAR