CHRONIC ANIMAL TESTING OF NEW CARDIAC PACING ELECTRODES

被引:9
作者
ADLER, S
SPEHR, P
ALLEN, J
BLOCK, W
机构
[1] Intermedics, Inc., Angleton, Texas
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 12期
关键词
ELECTRODES; THRESHOLDS; LEAD DESIGN;
D O I
10.1111/j.1540-8159.1990.tb06912.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the electrical performance of new electrode technologies, 24 leads containing either carbon coated porous titanium (BIOPORE, (Intermedics, Inc., Freeport, TX)), iridium oxide (IROX), or iridium oxide coated with polyethylene glycol (IROX-PEG) electrodes (eight of each) were implanted into the ventricles of 12 canines. Stimulation threshold data was measured at regular intervals for 24 weeks. Low acute values were observed for all leads (0.32 +/- .13 V at 0.6 msec pulse width), but the IROX-PEG electrode demonstrated lower subchronic, peak, and chronic values. Compared to implant, the IROX-PEG electrodes' stimulation thresholds rose only 0.23 V when chronic conditions occurred. There were no significant differences between the electrodes in pacing impedance or R wave amplitude measurements. We conclude that both IROX and IROX-PEG technologies represent a promising approach to the design of more efficient cardiac pacing leads.
引用
收藏
页码:1896 / 1900
页数:5
相关论文
共 16 条
[1]   POROUS ENDOCARDIAL ELECTRODE [J].
AMUNDSON, DC ;
MCARTHUR, W ;
MOSHARRAFA, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (01) :40-50
[2]   COMPOSITE ELECTRODE TIPS CONTAINING EXTERNALLY PLACED DRUG RELEASING COLLARS [J].
BREWER, G ;
MATHIVANAR, R ;
SKALSKY, M ;
ANDERSON, N .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1760-1769
[3]   STRENGTH-DURATION CURVES OF FIXED PULSE WIDTH VARIABLE TILT TRUNCATED EXPONENTIAL WAVEFORMS FOR NONTHORACOMY INTERNAL DEFIBRILLATION IN DOGS [J].
CHAPMAN, PD ;
WETHERBEE, JN ;
VETTER, JW ;
TROUP, P ;
SOUZA, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (07) :1045-1050
[4]   LONG-TERM THRESHOLD STABILITY WITH POROUS TIP ELECTRODES [J].
GOULD, L ;
PATEL, C ;
BECKER, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1202-1205
[5]   LONG-TERM PERFORMANCE OF ENDOCARDIAL LEADS WITH STEROID-ELUTING ELECTRODES [J].
KRUSE, IM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1217-1219
[6]   ACUTE AND LONG-TERM ATRIAL AND VENTRICULAR STIMULATION THRESHOLDS WITH A STEROID-ELUTING ELECTRODE [J].
KRUSE, IM ;
TERPSTRA, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (01) :45-49
[7]   ACUTE VOLTAGE, CHARGE, AND ENERGY THRESHOLDS AS FUNCTIONS OF ELECTRODE SIZE FOR ELECTRICAL-STIMULATION OF THE CANINE HEART [J].
LINDEMANS, FW ;
ZIMMERMAN, ANE .
CARDIOVASCULAR RESEARCH, 1979, 13 (07) :383-391
[8]  
MACGREGOR DC, 1979, J THORAC CARDIOV SUR, V78, P281
[9]   A COMPARISON OF PLATINIZED GROOVED ELECTRODE PERFORMANCE WITH RING-TIP ELECTRODES [J].
MIDEI, MG ;
JONES, BR ;
BRINKER, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (05) :752-756
[10]   THE POROUS TITANIUM STEROID ELUTING ELECTRODE - A DOUBLE-BLIND STUDY ASSESSING THE STIMULATION THRESHOLD EFFECTS OF STEROID [J].
MOND, H ;
STOKES, K ;
HELLAND, J ;
GRIGG, L ;
KERTES, P ;
PATE, B ;
HUNT, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (02) :214-219