DETECTION OF BIOACTIVE OLIGOPEPTIDES AFTER MICROBORE HPLC WITH ELECTROCHEMICAL DETECTION OF THEIR CU(II) COMPLEXES - EFFECT OF OPERATING PARAMETERS ON SENSITIVITY AND SELECTIVITY

被引:27
作者
CHEN, JG [1 ]
WEBER, SG [1 ]
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
关键词
D O I
10.1021/ac00115a033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We used a microbore reversed phase column for acetonitrile/0.1% aqueous TFA gradient elution separation of peptides with the detection of their copper complexes bq electrochemical detection, The copper complexes are formed in a short (1 or 1.5 min) postcolumn reader following mixing of the eluent with the postcolumn reaction phase, Detection can be at an upstream anode or a downstream cathode of a dual-electrode electrochemical detector. The following parameters have been investigated for their effect on the sensitivity and the selectivity of the procedure: postcolumn pH, buffer type, temperature, reaction time, and anode potential, Of the 23 bioactive peptides used, there are several that fall into classes according to their chemical and electrochemical behavior with copper(II): those with a blocked terminal amine, those with aspartate in the third position, those that have an electroactive amino acid, and those that have a cyclic structure formed by the amide backbone through a Cys-Cys disulfide bridge. Depending on these attributes, the operating parameters have an influence on the sensitivity of the determination, Among the more well-defined results are the following. Uncomplicated peptides with a free amine terminus react rapidly in the postcolumn reader and give signals in the range predicted by theory, There is evidence that longer peptides, and those with a blocked amine terminus, have a sensitivity limited by kinetic factors. The oxidations of tyrosine and tryptophan in peptides are dramatically influenced by buffer type at pH 9.8, At pH 8.0, there is no signal from several peptides in phosphate buffer, while in berate there is a signal.
引用
收藏
页码:3596 / 3604
页数:9
相关论文
共 28 条
[1]  
ALBERY WJ, 1971, RING DISC ELECTRODES, P122
[2]   ECE AND DISPROPORTIONATION .5. STATIONARY STATE GENERAL SOLUTION APPLICATION TO LINEAR SWEEP VOLTAMMETRY [J].
AMATORE, C ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1977, 85 (01) :27-46
[3]   FLUORESCENT N-METHYLANTHRANILYL (MANTYL) TAG FOR PEPTIDES - ITS APPLICATION IN SUBPICOMOLE DETERMINATION OF KININS [J].
ANUMULA, KR ;
SCHULZ, RP ;
BACK, N .
PEPTIDES, 1992, 13 (04) :663-669
[4]  
BOSSU FP, 1976, J AM CHEM SOC, V99, P2195
[5]   DEVELOPMENT OF A HECD LASER-BASED FLUORESCENCE DETECTOR FOR ANALYSIS OF DERIVATIZED BIOGENIC-AMINES [J].
BOSTICK, JM ;
STROJEK, JW ;
METCALF, T ;
KUWANA, T .
APPLIED SPECTROSCOPY, 1992, 46 (10) :1532-1539
[6]   SENSITIVITY AND SELECTIVITY OF THE ELECTROCHEMICAL DETECTION OF THE COPPER(II) COMPLEXES OF BIOACTIVE PEPTIDES, AND COMPARISON TO MODEL STUDIES BY ROTATING RING-DISC ELECTRODE [J].
CHEN, JG ;
WOLTMAN, SJ ;
WEBER, SG .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :301-315
[7]   CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CONDITIONAL EQUILIBRIUM-CONSTANTS FOR THE CARBAMATE FORMATION REACTION FROM AMINO-ACIDS AND PEPTIDES IN AQUEOUS-SOLUTION [J].
CHEN, JG ;
SANDBERG, M ;
WEBER, SG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) :7343-7350
[8]  
CHEN JG, 1995, J CHROMATOGR A, V105, P171
[9]   REDUCTION OF REEQUILIBRATION TIME FOLLOWING GRADIENT ELUTION REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
COLE, LA ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :16-21
[10]   THE REDUCTION OF FLUORESCEIN IN AQUEOUS-SOLUTION (AT PH-6) - A NEW DISP2 REACTION [J].
COMPTON, RG ;
MASON, D ;
UNWIN, PR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1988, 84 :483-489