OPTIMAL TIMING OF ABDOMINAL CT IN CHILDREN - RELATIONSHIP TO INJECTION RATE

被引:11
作者
KUHNS, LR
机构
[1] Department of Pediatric Imaging, Children's Hospital of Michigan, Detroit, MI 48201-2196
关键词
ABDOMEN; CT; COMPUTED TOMOGRAPHY (CT); IN INFANTS AND CHILDREN; KIDNEY; LIVER;
D O I
10.1148/radiology.189.1.8372218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To study computed tomographic (CT) scanning technique in relationship to rate of injection of contrast material for imaging of the liver and other abdominal organs in pediatric patients. MATERIALS AND METHODS: The time from start of injection of 2 mL/kg iohexol to peak opacification in the aorta, hepatic vein, liver, and kidney was determined for injection rates of 0-0.99, 1.00-1.99, 2.00-2.99, 3.00-3.99, and 4.00 mL/kg or more per minute in 77 pediatric patients. RESULTS: Peak liver opacification varied only slightly with different injection rates, but the time from start of injection to peak opacification in the aorta, hepatic vein, liver, and kidney did vary with injection rate. CONCLUSION: Data provided by this study should allow CT scanning to be timed in relation to injection rate to ensure that maximal organ opacification is achieved as the middle of the organ is being scanned, that adequate hepatic and portal vein opacification is achieved, and that streaking from the renal pelvis is minimized.
引用
收藏
页码:49 / 51
页数:3
相关论文
共 10 条
  • [1] CONTRAST ENHANCEMENT IN ABDOMINAL CT - BOLUS VS INFUSION
    BURGENER, FA
    HAMLIN, DJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) : 351 - 358
  • [2] CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING
    FOLEY, WD
    BERLAND, LL
    LAWSON, TL
    SMITH, DF
    THORSEN, MK
    [J]. RADIOLOGY, 1983, 147 (03) : 797 - 803
  • [3] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [4] HALVORSEN RA, 1984, INVEST RADIOL S, V19, P239
  • [5] CT OF NON-CYSTIC LIVER-LESIONS - BOLUS ENHANCEMENT
    MARCHAL, GJ
    BAERT, AL
    WILMS, GE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (01) : 57 - 65
  • [6] THE USE OF A FLOW-RATE INJECTOR FOR CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY
    MCCARTHY, S
    MOSS, AA
    [J]. RADIOLOGY, 1984, 151 (03) : 800 - 800
  • [7] CONTRAST-ENHANCED CT OF THE LIVER AND SPLEEN - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS
    NELSON, RC
    CHEZMAR, JL
    PETERSON, JE
    BERNARDINO, ME
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) : 973 - 976
  • [8] HEPATIC DYNAMIC SEQUENTIAL CT - SECTION ENHANCEMENT PROFILES WITH A BOLUS OF IONIC AND NONIONIC CONTRAST AGENTS
    NELSON, RC
    MOYERS, JH
    CHEZMAR, JL
    HOEL, MJ
    JONES, EC
    PETERSON, JE
    CORK, RD
    BERNARDINO, ME
    [J]. RADIOLOGY, 1991, 178 (02) : 499 - 502
  • [9] ROBBINS AH, 1984, INVEST RADIOL S, V19, P234
  • [10] USE OF A POWER INJECTOR DURING DYNAMIC COMPUTED-TOMOGRAPHY
    SHUMAN, WP
    ADAM, JL
    SCHOENECKER, SA
    TAZIOLI, PR
    MOSS, AA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (06) : 1000 - 1002