ADAPTATION OF A GLOW-DISCHARGE MASS-SPECTROMETER IN A GLOVE-BOX FOR THE ANALYSIS OF NUCLEAR-MATERIALS

被引:18
作者
BETTI, M [1 ]
RASMUSSEN, G [1 ]
HIERNAUT, T [1 ]
KOCH, L [1 ]
MILTON, DMP [1 ]
HUTTON, RC [1 ]
机构
[1] FISONS INSTRUMENTS,VG ELEMENTAL,WINSFORD CW7 3BX,CHESHIRE,ENGLAND
关键词
GLOW DISCHARGE MASS SPECTROMETRY; GLOVE-BOX; NUCLEAR MATERIAL;
D O I
10.1039/ja9940900385
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A VG9000 glow discharge mass spectrometer has been modified for the direct analysis of solid nuclear samples within a glove-box environment. Because containment is needed for the analysis of this kind of material, the glove-box encloses all parts of the instrument that come into contact with the sample, namely the ion source chamber, sample interlock and associated pumping system. External modifications eliminate outside contamination by the fitting of absolute filters on all source supplies. Internally, the design of the ion source has been altered to minimize the number of operations performed inside the glove-box thereby simplifing operation and routine maintenance. These modifications retain the ion extraction and focusing properties of the instrument. The data presented show that there is no compromise in the analytical performance of the instrument when placed in the glove-box. Data representative of nuclear materials is also shown.
引用
收藏
页码:385 / 391
页数:7
相关论文
共 16 条
[1]   PERFORMANCE-CHARACTERISTICS OF A GLOVE BOX INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER FOR THE ANALYSIS OF NUCLEAR-MATERIALS [J].
ALONSO, JIG ;
THOBYSCHULTZENDORFF, D ;
GIOVANONNE, B ;
KOCH, L ;
WIESMANN, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (05) :673-679
[2]   A PLASMA DISCHARGE SOURCE-MASS SPECTROMETER FOR INORGANIC ANALYSIS [J].
CANTLE, JE ;
HALL, EF ;
SHAW, CJ ;
TURNER, PJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 46 (JAN) :11-13
[3]   PLASMA DIAGNOSTICS OF AN RF-SPUTTERING GLOW DISCHARGE [J].
COBURN, JW ;
KAY, E .
APPLIED PHYSICS LETTERS, 1971, 18 (10) :435-&
[4]   SCINTILLATION TYPE MASS SPECTROMETER ION DETECTOR [J].
DALY, NR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (03) :264-267
[5]   TABLE OF THE ISOTOPIC COMPOSITION OF THE ELEMENTS AS DETERMINED BY MASS-SPECTROMETRY [J].
DEBIEVRE, P ;
BARNES, IL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 65 (1-2) :211-230
[6]  
DENOYER E, 1982, ANAL CHEM, V54, pA26
[7]   RADIOFREQUENCY CAVITY ION-SOURCE IN SOLIDS MASS-SPECTROMETRY [J].
DONOHUE, DL ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1975, 47 (09) :1528-1531
[8]   RADIO-FREQUENCY POWERED GLOW-DISCHARGE ATOMIZATION IONIZATION SOURCE FOR SOLIDS MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1879-1886
[9]   SAMPLE PREPARATION OF HIGH-PURITY TITANIUM FOR ANALYSIS BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
FANG, DC ;
SEEGOPAUL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :959-964
[10]  
HARRISON WW, 1988, INORGANIC MASS SPECT