QUANTITATIVE HPLC/ETAAS HYBRID METHOD WITH AN ONLINE METAL SCAVENGER FOR STUDYING THE PROTEIN-BINDING AND SPECIATION OF ALUMINUM AND IRON

被引:58
作者
VANLANDEGHEM, GF [1 ]
DHAESE, PC [1 ]
LAMBERTS, LV [1 ]
DEBROE, ME [1 ]
机构
[1] UNIV ANTWERP,DEPT NEPHROL HYPERTENS,ANTWERP,BELGIUM
关键词
D O I
10.1021/ac00074a007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quantitative metal-free high-performance liquid chromato-graphic/electrothermal atomic absorption spectrometric (HPLC/ETAAS) technique allowing an adequate separation of the proteins and of the inorganic/organic metal species of interest was developed. A silica-based scavenger was placed proximal to the injection valve retaining any remaining Al and Fe originating from buffer solutions and recipients. ETAAS instrumental conditions and matrix modifiers were carefully selected to eliminate interferences occurring due to the salt gradient elution. The postelution Al recovery (143-1428 mu g L(-1); 100-mu L sample volume) was found to be 100.1 +/- 15.3% (N = 50) whereas that of Fe was 97.3 +/- 2.0% (N = 20; 442-2653 mu g L(-1)). The protein recovery varied between 95 and 105%. The HPLC/ETAAS intraassay CV (N= 3) was 8.0% for Al (eluted amount of Al bound to transferrin (Tf), 7.3 ng) whereas that of Fe was 1.4% (eluted amount of Fe bound to Tf, 124.8 ng). The intraassay CV of the HPLC Tf determination was 1.6%. The proposed method is sensitive and accurate, allowing for the first time quantitative evaluation of the competition between Al and Fe for protein binding at clinical relevant concentrations. The technique will also be used for studying the protein binding of elements other than Al and Fe.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 35 条
[1]   IRON TRANSPORT AND STORAGE PROTEINS [J].
AISEN, P ;
LISTOWSKY, I .
ANNUAL REVIEW OF BIOCHEMISTRY, 1980, 49 :357-393
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHODS FOR STUDYING PROTEIN-BINDING OF ALUMINUM IN HUMAN SERUM IN THE ABSENCE AND IN THE PRESENCE OF DESFERRIOXAMINE [J].
ALONSO, JIG ;
GARCIA, AL ;
PARAJON, JP ;
GONZALEZ, EB ;
MEDEL, AS ;
CANNATA, JB .
CLINICA CHIMICA ACTA, 1990, 189 (01) :69-80
[3]  
BERTHOLF RL, 1985, CLIN PHYSIOL BIOCH, V3, P271
[4]   ALUMINUM INTERACTION WITH GA-67 UPTAKE BY HUMAN-PLASMA AND TRANSFERRIN [J].
COCHRAN, M ;
NEOH, S ;
STEPHENS, E .
CLINICA CHIMICA ACTA, 1983, 132 (02) :199-203
[5]  
DATTA AK, 1990, J TRACE ELEM ELECT H, V4, P107
[6]  
DEBROE ME, 1990, ALUMINUM RENAL FAILU
[7]  
DHAESE PC, 1985, CLIN CHEM, V31, P24
[8]   VALUE OF SERUM ALUMINUM MONITORING IN DIALYSIS PATIENTS - A MULTICENTER STUDY [J].
DHAESE, PC ;
CLEMENT, JP ;
ELSEVIERS, MM ;
LAMBERTS, LV ;
VANDEVYVER, FL ;
VISSER, WJ ;
DEBROE, ME .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1990, 5 (01) :45-53
[9]  
DRISCOLL CT, 1981, ALUMINIUM HLTH, pCH2
[10]   DEFECTIVE GALLIUM-TRANSFERRIN BINDING IN ALZHEIMER-DISEASE AND DOWN SYNDROME - POSSIBLE MECHANISM FOR ACCUMULATION OF ALUMINUM IN BRAIN [J].
FARRAR, G ;
ALTMANN, P ;
WELCH, S ;
WYCHRIJ, O ;
GHOSE, B ;
LEJEUNE, J ;
CORBETT, J ;
PRASHER, V ;
BLAIR, JA .
LANCET, 1990, 335 (8692) :747-750