FLUORIM - A COMPUTER-PROGRAM FOR THE AUTOMATED DATA-COLLECTION AND TREATMENT USING COMMERCIAL SPECTROFLUORIMETERS

被引:3
作者
BERRUETA, LA
FERNANDEZ, LA
VICENTE, F
机构
[1] Department of Analytical Chemistry, University of País Vasco, 48080 Bilbao
来源
COMPUTERS & CHEMISTRY | 1991年 / 15卷 / 04期
关键词
D O I
10.1016/0097-8485(91)80048-Q
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A general purpose program that uses a PC microcomputer has been designed for the control of experiments in fluorimetry. This program allows the digital collection of the main types of scans that a commercial spectrofluorimeter can perform: emission, excitation and synchronic; as well as the measurement of the fluorescent intensity as a function of time. The program also allows a series of operations with previously stored spectra. These operations include screen and paper plots of the spectra, calculation of linear combinations of them and the nine first derivatives, as well as their relative maxima and minima.
引用
收藏
页码:307 / 312
页数:6
相关论文
共 25 条
[11]   OIL-MATCHING BY USING A SIMPLE VECTOR MODEL FOR FLUORESCENCE-SPECTRA [J].
KILLEEN, TJ ;
EASTWOOD, D ;
HENDRICK, MS .
TALANTA, 1981, 28 (01) :1-6
[12]   AUTOMATED FLOW-INJECTION PSEUDOTITRATION OF STRONG AND WEAK ACIDS, ASCORBIC-ACID AND CALCIUM, AND CATALYTIC PSEUDOTITRATIONS OF AMINOPOLYCARBOXYLIC ACIDS BY USE OF A MICROCOMPUTER-CONTROLLED ANALYZER [J].
KOUPPARIS, MA ;
ANAGNOSTOPOULOU, P ;
MALMSTADT, HV .
TALANTA, 1985, 32 (05) :411-417
[13]   PATTERN-RECOGNITION FOR IDENTIFICATION AND QUANTITATION OF COMPLEX-MIXTURES IN CHROMATOGRAPHY [J].
LEA, RE ;
BRAMSTONCOOK, R ;
TSCHIDA, J .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :626-629
[14]   PARTIAL LEAST-SQUARES METHOD FOR SPECTROFLUORIMETRIC ANALYSIS OF MIXTURES OF HUMIC-ACID AND LIGNINSULFONATE [J].
LINDBERG, W ;
PERSSON, JA ;
WOLD, S .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :643-648
[15]   COMPUTER-ASSISTED STRUCTURAL INTERPRETATION OF FLUORESCENCE-SPECTRA [J].
MILLER, TC ;
FAULKNER, LR .
ANALYTICAL CHEMISTRY, 1976, 48 (14) :2083-2088
[16]   A SOFTWARE PACKAGE FOR COMPUTER-CONTROLLED FLOW-INJECTION ANALYSIS [J].
PROP, LTM ;
THIJSSEN, PC ;
VANDONGEN, LGG .
TALANTA, 1985, 32 (03) :230-234
[17]  
PUIGDOMENECH I, 1986, COMMUNICATION
[18]   ANALYSIS OF BINARY-MIXTURES BY COMPUTER DECOMPOSITION OF MOLECULAR FLUORESCENCE-SPECTRA [J].
RECHSTEINER, CE ;
GOLD, HS ;
BUCK, RP .
ANALYTICA CHIMICA ACTA, 1977, 95 (1-2) :51-58
[19]   MICROCOMPUTER FLUOROMETER FOR CORRECTED, DERIVATIVE, AND DIFFERENTIAL SPECTRA AND QUANTUM YIELD DETERMINATIONS [J].
RITTER, AW ;
TWAY, PC ;
LOVE, LJC ;
ASHWORTH, HA .
ANALYTICAL CHEMISTRY, 1981, 53 (02) :280-284
[20]   A MULTIVARIATE CALIBRATION-PROBLEM IN ANALYTICAL-CHEMISTRY SOLVED BY PARTIAL LEAST-SQUARES MODELS IN LATENT-VARIABLES [J].
SJOSTROM, M ;
WOLD, S ;
LINDBERG, W ;
PERSSON, JA ;
MARTENS, H .
ANALYTICA CHIMICA ACTA, 1983, 150 (01) :61-70