CALORIMETER TESTS WITH LIQUID IONIZATION CHAMBERS

被引:10
作者
ENGLER, J
GETTERT, M
KEIM, H
KNAPP, J
MIELKE, HH
AREFIEV, A
KAMYSHKOV, Y
MALININ, A
ONOPRIENKO, D
SAVIN, A
SHMAKOV, K
TARKOVSKY, E
VOROBIEV, I
机构
[1] UNIV KARLSRUHE,W-7500 KARLSRUHE,GERMANY
[2] MOSCOW THEORET & EXPTL PHYS INST,MOSCOW 117259,USSR
关键词
D O I
10.1016/0168-9002(92)90942-W
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Configurations of sampling calorimeters with iron, lead and uranium as absorbers have been investigated using liquid ionization chambers as active elements. As liquid tetramethylsilane has been used. Results of beam tests with electrons, pions and muons in the energy range of 2 to 6 GeV are presented and compared with Monte Carlo simulations. In particular the questions regarding which configuration can compensate and the separation of sampling from intrinsic fluctuations have been studied.
引用
收藏
页码:460 / 470
页数:11
相关论文
共 22 条
[1]   PERFORMANCE OF THE URANIUM PLASTIC SCINTILLATOR CALORIMETER FOR THE HELIOS EXPERIMENT AT CERN [J].
AKESSON, T ;
ANGELIS, ALS ;
CORRIVEAU, F ;
DEVENISH, RCE ;
DITORE, G ;
FABJAN, CW ;
LAMARCHE, F ;
LEROY, C ;
MCCUBBIN, ML ;
MCCUBBIN, NA ;
OLSEN, LH ;
SEMAN, M ;
SIROIS, Y ;
WIGMANS, R ;
WILLIS, WJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3) :243-263
[2]   PROPERTIES OF A FINE-SAMPLING URANIUM-COPPER SCINTILLATOR HADRON CALORIMETER [J].
AKESSON, T ;
BATLEY, R ;
BENARY, O ;
BERSET, JC ;
BOTNER, O ;
BURNS, M ;
CLELAND, WE ;
DAGAN, S ;
DAM, P ;
DELAVALLADE, G ;
DICIACCIO, A ;
DITORE, G ;
FABJAN, CW ;
GORDON, HA ;
HARRIS, M ;
JEFFREYS, PW ;
KESSELER, G ;
LINDSAY, J ;
LISSAUER, D ;
MOLZON, W ;
NIELSEN, BS ;
OLSEN, L ;
OREN, Y ;
RENAUD, J ;
ROSSELET, L ;
SCHINDLER, R ;
STUMER, I ;
VANDERLANS, J ;
VELLA, E ;
WANG, CJ ;
WIGMANS, R ;
WILLIS, WJ ;
WINIK, M ;
WITZELING, W ;
WOODY, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (01) :17-42
[3]   RESPONSE OF A URANIUM SCINTILLATOR CALORIMETER TO ELECTRONS, PIONS AND PROTONS IN THE MOMENTUM RANGE 0.5-10 GEV/C [J].
ANDRESEN, A ;
BAMBERGER, A ;
BEHRENS, U ;
CRITTENDEN, J ;
CALDWELL, A ;
DAWSON, J ;
ENGELEN, J ;
FRISKEN, B ;
GILKINSON, D ;
HAMATSU, R ;
HANNA, D ;
HASELL, D ;
HERVAS, L ;
HOLM, U ;
FURTJES, A ;
KLANNER, R ;
KOOIJMAN, P ;
KOTZ, U ;
KRAMER, M ;
KRUGER, J ;
LEVMAN, G ;
MALECKI, P ;
MARTIN, J ;
MITCHELL, J ;
PATEL, P ;
ROHDE, M ;
ROMANOWSKI, T ;
ROS, E ;
SIPPACH, W ;
SCHACKE, D ;
STRAVER, J ;
TIECKE, H ;
TSURUGAI, T ;
VOGEL, W ;
WICK, K ;
YOUNGMAN, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 290 (01) :95-108
[4]  
[Anonymous], 1964, THEORY PRACTICE SCIN
[5]   PERFORMANCE OF A COMPENSATING LEAD SCINTILLATOR HADRONIC CALORIMETER [J].
BERNARDI, E ;
DREWS, G ;
GARCIA, MA ;
KLANNER, R ;
KOTZ, U ;
LEVMAN, G ;
LOMPERSKI, M ;
LUKE, D ;
ROS, E ;
SELONKE, F ;
TIECKE, H ;
TSIROU, M ;
VOGEL, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3) :229-242
[6]  
BRUCKMANN H, 1987, DESY87064 REP
[7]  
BRUN R, 1987, CERN DDEE841 REP
[8]   EXPERIMENTAL-STUDY OF URANIUM PLASTIC SCINTILLATOR CALORIMETERS [J].
DAGOSTINI, G ;
BAMBERGER, A ;
BARREIRO, F ;
BERNARDI, E ;
DIERKS, K ;
DREWS, G ;
ENGELEN, J ;
GARCIA, M ;
KLANNER, R ;
KOTZ, U ;
KRUGER, J ;
LEVMAN, G ;
LUKE, D ;
MARTIN, J ;
ROS, E ;
SELONKE, F ;
VANDERSTAD, R ;
STRAVER, J ;
TIECKE, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2) :134-144
[9]  
DOLL P, 1990, KFK4686 REP
[10]   EXPERIMENTAL-DETERMINATION OF SAMPLING FLUCTUATIONS IN URANIUM AND LEAD HADRONIC CALORIMETERS [J].
DREWS, G ;
GARCIA, MA ;
KLANNER, R ;
KOTZ, U ;
KRAMER, M ;
DELPESO, J ;
ROS, E ;
SELONKE, F ;
STRAVER, J ;
TIECKE, H ;
TSIROU, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 290 (2-3) :335-345