ADAPTING HOMOGENEOUS ENZYME-LINKED COMPETITIVE-BINDING ASSAYS TO MICROTITER PLATES

被引:13
作者
KIM, B [1 ]
BUCKWALTER, JM [1 ]
MEYERHOFF, ME [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
D O I
10.1006/abio.1994.1135
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recently devised homogeneous enzyme-linked binding assays useful for the rapid detection of carbohydrate structure/content of intact glycoproteins (via use of lectins as binders) and for quantitating given vitamins (e.g., biotin; using soluble binding proteins) are adapted successfully to a microtiter plate reader format. The problem of nonspecific adsorption of the binders and enzyme-saccharide/vitamin conjugates is solved via the addition of Tween 20 to the assay buffer. More convenient and reliable photometric detection of the preferred labeling enzyme, glucose-6-phosphate dehydrogenase (G6PDH), is accomplished by monitoring the rate of generation of reduced thio-NAD (from thio-NAD) at 405 nm instead of NADH (from NAD) at 340 nm. By employing these modifications it is shown that homogeneous enzyme-linked binding assays can be readily adapted to microtiter plates without loss in analytical assay performance. Results further suggest that other homogeneous assays based on G6PDH, including commercial EMIT assays used routinely in clinical chemistry laboratories for detecting drugs of abuse, could, in principle, be run on microtiter plates to significantly enhance sample throughput. (C) 1994 Academic Press, Inc.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 23 条
[1]   THIONICOTINAMIDE ANALOGS OF DPN AND TPN .2. ENZYME STUDIES [J].
ANDERSON, BM ;
LEE, JK ;
ANDERSON, CD ;
STEIN, AM .
BIOCHEMISTRY, 1963, 2 (05) :1017-&
[2]   USE OF A 96-WELL MICROPLATE READER FOR MEASURING ROUTINE ENZYME-ACTIVITIES [J].
ASHOUR, MBA ;
GEE, SJ ;
HAMMOCK, BD .
ANALYTICAL BIOCHEMISTRY, 1987, 166 (02) :353-360
[3]   HOMOGENEOUS ENZYME-LINKED COMPETITIVE-BINDING ASSAY FOR THE RAPID-DETERMINATION OF FOLATE IN VITAMIN TABLETS [J].
BACHAS, LG ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :956-961
[4]   MICROTITER PLATE ASSAY FOR THE MEASUREMENT OF GLUTATHIONE AND GLUTATHIONE DISULFIDE IN LARGE NUMBERS OF BIOLOGICAL SAMPLES [J].
BAKER, MA ;
CERNIGLIA, GJ ;
ZAMAN, A .
ANALYTICAL BIOCHEMISTRY, 1990, 190 (02) :360-365
[5]   A CAUTIONARY NOTE ON THE USE OF LENTIL LECTIN AFFINITY-CHROMATOGRAPHY IN THE PRESENCE OF SODIUM DEOXYCHOLATE [J].
BARBER, BH ;
ARYA, S .
JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 48 (01) :87-95
[6]  
BUTLER JE, 1985, ENZYME MEDIATED IMMU, P241
[7]   A MICROTITER PLATE-BASED ASSAY FOR PHOSPHOENOLPYRUVATE CARBOXYLASE [J].
COCKBURN, W ;
WHITELAM, GC ;
SLOCOMBE, SP ;
MCKEE, RA .
ANALYTICAL BIOCHEMISTRY, 1990, 189 (01) :95-98
[8]   HOMOGENEOUS ENZYME-LINKED COMPETITIVE-BINDING ASSAY FOR BIOTIN BASED ON THE AVIDIN-BIOTIN INTERACTION [J].
DAUNERT, S ;
BACHAS, LG ;
MEYERHOFF, ME .
ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) :43-52
[9]  
DEBOIS M, 1956, ANAL CHEM, V28, P350
[10]  
FERNANDEZ AA, 1983, CLIN CHEM, V29, P284