APPLICATION OF RADIOLUMINOGRAPHY TO OFF-LINE COUNTING OF RADIOACTIVITY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ELUATES

被引:10
作者
BABA, S [1 ]
TERAZAWA, Y [1 ]
KIMATA, H [1 ]
SHINOHARA, Y [1 ]
AKIRA, K [1 ]
HASEGAWA, H [1 ]
机构
[1] KOWA CO LTD,TOKYO RES LABS,TOKYO 189,JAPAN
关键词
D O I
10.1016/0021-9673(94)80493-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An off-line counting method for the determination of carbon-14 in HPLC eluates was developed using radioluminography (RLG). A succession of aliquots of the eluate were collected in the flat-bottomed wells of a polystyrene microplate, evaporated to dryness and contacted with an imaging plate, and radioactivity was determined with a Bio-image analyser. The limit of detection was 0.35 Bq per injection. The inter-assay relative standard deviation was less than 3% over the range 2-20 Bq. The RLG off-line counting method was utilized to determine [C-14]eicosapentaenoic acid metabolites formed by rat hepatic microsomes. The results were compared with those obtained with an off-line liquid scintillation counting method and an on-line counting method.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 15 条
  • [1] PROFILING OF ARACHIDONIC-ACID METABOLITES IN RABBIT PLATELETS BY RADIO GAS-CHROMATOGRAPHY
    AKIRA, K
    NAKAMURA, T
    SHINOHARA, Y
    BABA, S
    [J]. LIPIDS, 1993, 28 (04) : 361 - 364
  • [2] LASER-STIMULATED LUMINESCENCE USED TO MEASURE X-RAY-DIFFRACTION OF A CONTRACTING STRIATED-MUSCLE
    AMEMIYA, Y
    WAKABAYASHI, K
    TANAKA, H
    UENO, Y
    MIYAHARA, J
    [J]. SCIENCE, 1987, 237 (4811) : 164 - 168
  • [3] IMAGING PLATE ILLUMINATES MANY FIELDS
    AMEMIYA, Y
    MIYAHARA, J
    [J]. NATURE, 1988, 336 (6194) : 89 - 90
  • [4] SYNCHRONIZED ACCUMULATING RADIOISOTOPE DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BABA, S
    HORIE, M
    WATANABE, K
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 244 (01): : 57 - 64
  • [5] DETERMINATION OF C-14 IN MICROPLATES BY RADIOLUMINOGRAPHY
    BABA, S
    KIMATA, H
    HARUKI, S
    SHINOHARA, Y
    [J]. APPLIED RADIATION AND ISOTOPES, 1993, 44 (07) : 1011 - 1014
  • [6] FURTHER STUDY OF THE SYNCHRONIZED ACCUMULATING RADIOISOTOPE DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BABA, S
    SUZUKI, Y
    SASAKI, Y
    HORIE, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 392 : 157 - 164
  • [7] METABOLIC-FATE OF A NEW ANTIULCER DRUG (+)-(1R,4AS,10AR)-1,2,3,4,4A,9,10,10A-OCTAHYDRO-1,4A-DIMETHYL-7-(1-METHYLETHYL)-6-SULFO-1-PHENANTHRENECARBOXYLIC ACID 6-SODIUM SALT PENTAHYDRATE (TA-2711) .2. DISTRIBUTION IN THE RAT STOMACH
    ITO, Y
    SUGAWARA, Y
    TAKAITI, O
    NAKAMURA, S
    [J]. JOURNAL OF PHARMACOBIO-DYNAMICS, 1991, 14 (09): : 547 - 554
  • [8] HIGH-SENSITIVITY RADIOASSAY OF CHROMATOGRAPHIC EFFLUENTS - AUTOMATIC FRACTION COLLECTOR/CONCENTRATOR FOR QUANTITATIVE AUTORADIOGRAPHY
    KARMEN, A
    MALIKIN, G
    FREUNDLICH, L
    LAM, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 349 (02): : 267 - 274
  • [9] HIGH-SENSITIVITY RADIOASSAY IN CHROMATOGRAPHIC EFFLUENTS
    KARMEN, A
    MALIKIN, G
    LAM, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1984, 302 (OCT): : 31 - 41
  • [10] Kawai K., 1988, SANKYO KENKYUSHO NEM, V40, P101