VARIABILITY OF MYOCARDIAL SIGNAL ON MAGNETIC-RESONANCE IMAGES

被引:6
作者
DEROOS, A
KUNDEL, HL
JOSEPH, PM
DOORNBOS, J
KRESSEL, HY
机构
[1] HOSP UNIV PENN,DEPT RADIOL,PHILADELPHIA,PA 19104
[2] INTERUNIV CARDIOL INST NETHERLANDS,UTRECHT,NETHERLANDS
关键词
D O I
10.1097/00004424-199009000-00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnosis of myocardial disease by magnetic resonance (MR) imaging depends on accurate measurement of myocardial signal intensity. The authors performed 15 experiments in four rabbits at 1.9 T with spin-echo MR imaging to study the variability of myocardial signal intensity throughout the cardiac cycle and to measure myocardial T2 values. Variability in signal from the myocardium throughout the cardiac cycle was observed in all experiments. During systole, a significant increase in myocardial signal was noted, when data acquisition was performed with electrocardiogram (ECG)-gating and controlled ventilation (P = .02). An inverse relationship between myocardial signal and phase noise was found, indicating the motion-related nature of the variation of myocardial signal. A similar inverse relationship was observed in images obtained from a normal human volunteer. Ex vivo myocardial T2 valnes of rabbit myocardial tissue were significantly higher than the in vivo values (P = .003), reflecting residual motion despite cardiac gating and controlled ventilation. © Lippincott-Raven Publishers.
引用
收藏
页码:1024 / 1028
页数:5
相关论文
共 11 条
[1]   VISUALIZATION OF MYOCARDIAL-INFARCTION AND SUBSEQUENT CORONARY REPERFUSION WITH MRI USING A DOG-MODEL [J].
AISEN, AM ;
BUDA, AJ ;
ZOTZ, RJ ;
BUCKWALTER, KA .
MAGNETIC RESONANCE IMAGING, 1987, 5 (05) :399-404
[2]  
CAMPBELL C F, 1986, Magnetic Resonance Imaging, V4, P473, DOI 10.1016/0730-725X(86)90025-1
[3]   DETECTION OF MYOCARDIAL-INFARCTION IN THE MINIPIG USING NMR IMAGING [J].
CHECKLEY, D ;
LOVEDAY, BE ;
WATERTON, JC ;
ZHU, XP ;
ISHERWOOD, I .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :201-216
[4]   MR IMAGING IN ASSESSMENT OF CARDIAC TRANSPLANT REJECTION IN HUMANS [J].
DOORNBOS, J ;
VERWEY, H ;
ESSED, CE ;
BALK, AHMM ;
DEROOS, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (01) :77-81
[5]  
EHMAN RL, 1984, EFFECT MOTION RELAXA, P208
[6]   DETECTION AND LOCALIZATION OF RECENT MYOCARDIAL-INFARCTION BY MAGNETIC-RESONANCE-IMAGING [J].
FILIPCHUK, NG ;
PESHOCK, RM ;
MALLOY, CR ;
CORBETT, JR ;
REHR, RB ;
BUJA, LM ;
JANSEN, DE ;
REDISH, GR ;
GABLIANI, GI ;
PARKEY, RW ;
WILLERSON, JT .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (03) :214-219
[7]   ACUTE MYOCARDIAL-INFARCTION - MR EVALUATION IN 29 PATIENTS [J].
FISHER, MR ;
MCNAMARA, MT ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :247-251
[8]  
GRODD W, 1983, FORTSCHR ROENTGENSTR, V3, P233
[9]   A METHOD FOR REDUCING MOTION INDUCED ERRORS IN T2-WEIGHTED MAGNETIC-RESONANCE-IMAGING [J].
JOSEPH, PM ;
SHETTY, A ;
BONAROTI, EA .
MEDICAL PHYSICS, 1987, 14 (04) :608-615
[10]   AN ESTIMATION AND CORRECTION SCHEME FOR SYSTEM IMPERFECTIONS IN MULTIPLE-ECHO MAGNETIC-RESONANCE-IMAGING [J].
MAJUMDAR, S ;
GMITRO, A ;
ORPHANOUDAKIS, SC ;
REDDY, D ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (03) :203-220