A HEURISTIC APPROACH TO EDGE-DETECTION IN ONLINE PORTAL IMAGING

被引:4
作者
MCGEE, KP
SCHULTHEISS, TE
MARTIN, EE
机构
[1] Department of Radiation Oncology, Fox Chase Cancer Center, Philadephia, PA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 32卷 / 04期
关键词
EDGE DETECTION; ELECTRONIC PORTAL IMAGING;
D O I
10.1016/0360-3016(94)00410-M
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Portal field edge detection is an essential component of several postprocessing techniques used in on-line portal imaging, including field shape verification, selective contrast enhancement, and treatment setup error detection. Currently edge detection of successive fractions in a multifraction portal image series involves the repetitive application of the same algorithm. As the number of changes in the field is small compared to the total number of fractions, standard edge detection algorithms essentially recalculate the same field shape numerous times. A heuristic approach to portal edge detection has been developed that takes advantage of the relatively few changes in the portal field shape throughout a fractionation series. Methods and Materials: The routine applies a standard edge detection routine to calculate an initial field edge and saves the edge information. Subsequent fractions are processed by applying an edge detection operator over a small region about each point of the previously defined contour, to determine any shifts in the field shape in the new image. Failure of this edge check indicates that a significant change in the field edge has occurred, and the original edge detection routine is applied to the image. Otherwise the modified edge contour is used to define the new edge. Results: Two hundred and eighty-one portal images collected from an electronic portal imaging device were processed by the edge detection routine. The algorithm accurately calculated each portal field edge, as well as reducing processing time in subsequent fractions of an individual portal field by a factor of up to 14. Conclusions: The heuristic edge detection routine is an accurate and fast method for calculating portal field edges and determining field edge setup errors.
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 24 条
[1]   DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
MCSHAN, DL ;
MORTON, EJ ;
YORKSTON, J ;
LONGO, MJ ;
STREET, RA .
MEDICAL PHYSICS, 1992, 19 (06) :1455-1466
[2]  
BAILY NA, 1980, INT J RADIAT ONCOL, V6, P935, DOI 10.1016/0360-3016(80)90341-7
[3]   AUTOMATIC VERIFICATION OF RADIATION-FIELD SHAPE USING DIGITAL PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1992, 19 (04) :1007-1014
[4]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[5]   CONTRAST ENHANCEMENT OF PORTAL IMAGES BY SELECTIVE HISTOGRAM EQUALIZATION [J].
CROOKS, I ;
FALLONE, BG .
MEDICAL PHYSICS, 1993, 20 (01) :199-204
[6]  
ELSZCZYNSKI KW, 1990, MED IMAGING 4 IMAGE, V1231, P401
[7]   IMAGE COMPARISON TECHNIQUES FOR USE WITH MEGAVOLTAGE IMAGING-SYSTEMS [J].
EVANS, PM ;
GILDERSLEVE, JQ ;
MORTON, EJ ;
SWINDELL, W ;
COLES, R ;
FERRARO, M ;
RAWLINGS, C ;
XIAO, ZR ;
DYER, J .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776) :701-709
[8]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677
[9]   AN ONLINE ELECTRONIC PORTAL IMAGING-SYSTEM FOR EXTERNAL BEAM RADIOTHERAPY [J].
LAM, KS ;
PARTOWMAH, M ;
LAM, WC .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (706) :1007-1013
[10]  
LAM WC, 1986, BRIT J RADIOL, V60, P361