COMPARATIVE-STUDY OF DIFFERENT APPROACHES FOR THE FLOW-INJECTION FOURIER-TRANSFORM INFRARED DETERMINATION OF TOLUENE IN GASOLINES

被引:7
作者
GALLIGNANI, M
GARRIGUES, S
DELAGUARDIA, M
BURGUERA, JL
BURGUERA, M
机构
[1] UNIV VALENCIA,DEPT ANALYT CHEM,50 DR MOLINER ST,E-46100 BURJASSOT,SPAIN
[2] UNIV LOS ANDES,MERIDA,VENEZUELA
关键词
D O I
10.1016/0039-9140(93)E0038-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single channel flow injection manifold has been employed to carry out the direct determination of toluene in gasolines by FT-IR without any sample pretreatment and by using different strategies. Toluene can be directly determined by measuring the absorbance at 728 cm-1, using a base line established between 835 and 575 cm-1; and in this case a limit of detection of 0.01% (v/v) can be obtained with a dynamic range up to 2% (v/v). In some cases it could be convenient to determine toluene by derivative flow-injection FT-IR in order to avoid matrix interferences in the analysis of some types of gasolines. Carrying out the first order derivative FI-FT-IR measurements on the 728 cm-1 band between the peak at 731 and the valley at 725 cm-1 toluene can be determined without problems in establishing the base line and with a limit of detection of 0.01% (v/v). On the other hand, the use of the quotient between the first order derivative absorbance values of toluene, at the 728 cm-1 band, and benzene, at the 675 cm-1 band, can be applied for the determination of toluene in gasolines in which benzene has been previously analyzed, avoiding problems related to the determination of the base line and making measurements independent of the spacer employed.
引用
收藏
页码:739 / 745
页数:7
相关论文
共 31 条
[1]   DETERMINATION OF PHENYL ISOCYANATE IN A FLOW-INJECTION SYSTEM WITH INFRARED SPECTROMETRIC DETECTION [J].
CURRAN, DJ ;
COLLIER, WG .
ANALYTICA CHIMICA ACTA, 1985, 177 :259-262
[2]   FLOW-INJECTION DERIVATIVE FOURIER-TRANSFORM INFRARED DETERMINATION OF METHYL TERT-BUTYL ETHER IN GASOLINES [J].
DELAGUARDIA, M ;
GALLIGNANI, M ;
GARRIGUES, S .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :543-550
[3]   FLOW-INJECTION FOURIER-TRANSFORM INFRARED SPECTROMETRIC ANALYSIS [J].
DELAGUARDIA, M ;
GARRIGUES, S ;
GALLIGNANI, M ;
BURGUERA, JL ;
BURGUERA, M .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :53-57
[4]   IDENTIFICATION OF SOLVENTS OF ABUSE USING GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY AFTER HEADSPACE SAMPLING [J].
DEVEAUX, M ;
HUVENNE, JP .
CHROMATOGRAPHIA, 1987, 23 (09) :626-630
[5]   DETERMINATION OF CARBARYL IN PESTICIDE FORMULATIONS BY FOURIER-TRANSFORM INFRARED SPECTROMETRY WITH FLOW-ANALYSIS [J].
GALLIGNANI, M ;
GARRIGUES, S ;
MARTINEZVADO, A ;
DELAGUARDIA, M .
ANALYST, 1993, 118 (08) :1043-1048
[6]   DIRECT DETERMINATION OF BENZENE IN GASOLINE BY FLOW-INJECTION FOURIER-TRANSFORM INFRARED SPECTROMETRY [J].
GALLIGNANI, M ;
GARRIGUES, S ;
DELAGUARDIA, M .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :267-274
[7]   DIRECT DETERMINATION OF ETHANOL IN ALL TYPES OF ALCOHOLIC BEVERAGES BY NEAR-INFRARED DERIVATIVE SPECTROMETRY [J].
GALLIGNANI, M ;
GARRIGUES, S ;
DELAGUARDIA, M .
ANALYST, 1993, 118 (09) :1167-1173
[8]  
GALLIGNANI M, 1993, 28 CSI YORK
[9]  
GALLIGNANI M, 1992, JAN WCFIA 92
[10]  
GALLIGNANI M, 1991, 27 CSI BERG