FLOW CYTOMETRIC DETECTION OF MICRONUCLEI BY COMBINED STAINING OF DNA AND MEMBRANES

被引:21
作者
WESSELS, JM
NUSSE, M
机构
[1] GSF-Forschungszentrum für Umwelt und Gesundheit, Institut für Biophysikalische Strahlenforschung, Oberschleißheim
来源
CYTOMETRY | 1995年 / 19卷 / 03期
关键词
UV-B-INDUCED MICRONUCLEI; AUTOMATION OF MICRONUCLEUS SCORING; NOW CYTOMETRY; MEMBRANE-SPECIFIC DYES;
D O I
10.1002/cyto.990190303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new staining method is presented for now cytometric measurement of micronuclei (MN) in cell cultures and human lymphocytes using membrane-specific fluorescent dyes in addition to DNA staining. Several combinations of fluorescent membrane and DNA dyes were studied for a better discrimination of MN from debris in a suspension of nuclei and micronuclei, For staining of membranes, the lipophilic dyes 2-hydroxyethyl-7,12,17-tris(methoxyethyl)porphycene (HEPn) and 1,6-diphenyl-1,3,5-hexatriene (DPH) were used in combination with ethidium bromide (EB), proflavine (PF), and Hoechst 33258 (HO). Due to their spectral properties, HO or EB combined with HEPn were not as suitable for the discrimination of MN from debris as was HEPn in combination with PF, With HEPn in combination with PF, however, additional noise was found at low fluorescence intensities, probably due to free fluorescent dye molecules in the solution. The optimal simultaneous staining of membranes and DNA was obtained using a combination of DPH and EB. The induction of MN in Chinese hamster and mouse NIH-3T3 cells by UV-E illumination was studied with this new staining technique. UV-B illumination (280-360 nm) induced MN in both cell lines. Chinese hamster cells were found to be more sensitive to these wavelengths. Illumination with wavelengths above 360 nm did not induce MN in either cell Line, The results obtained from human lymphocytes using the combination of EB and DPH were comparable to the results obtained with the combination of EB and HO. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 23 条
[11]   MICROSCOPIC AND FLOW CYTOMETRIC STUDY OF MICRONUCLEI IN IODODEOXYURIDINE LABELED CELLS IRRADIATED WITH SOFT X-RAYS [J].
LUDWIKOW, G ;
STALNACKE, CG ;
JOHANSON, KJ ;
SUNDELLBERGMAN, S ;
RICHTER, S .
ACTA ONCOLOGICA, 1990, 29 (06) :761-767
[12]   FACTORS INFLUENCING THE DNA CONTENT OF RADIATION-INDUCED MICRONUCLEI [J].
NUSSE, M ;
KRAMER, J ;
MILLER, BM .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1992, 62 (05) :587-602
[13]   FLOW CYTOMETRIC ANALYSIS OF MICRONUCLEI FOUND IN CELLS AFTER IRRADIATION [J].
NUSSE, M ;
KRAMER, J .
CYTOMETRY, 1984, 5 (01) :20-25
[14]   MICRONUCLEI INDUCED BY 2-CHLOROBENZYLIDENE MALONITRILE CONTAIN SINGLE CHROMOSOMES AS DEMONSTRATED BY THE COMBINED USE OF FLOW-CYTOMETRY AND IMMUNOFLUORESCENT STAINING WITH ANTI-KINETOCHORE ANTIBODIES [J].
NUSSE, M ;
RECKNAGEL, S ;
BEISKER, W .
MUTAGENESIS, 1992, 7 (01) :57-67
[15]  
PINCU M, 1985, INT J RADIAT BIOL, V74, P423
[16]   A LONG-TIME-STABLE LIPOSOME FORMULATION FOR PORPHYRINOID PHOTOSENSITIZERS [J].
RICHERT, C .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1993, 19 (01) :67-69
[17]   AN AUTOMATED FLOW CYTOMETRIC MICRONUCLEUS ASSAY FOR HUMAN-LYMPHOCYTES [J].
SCHREIBER, GA ;
BEISKER, W ;
BRASELMANN, H ;
BAUCHINGER, M ;
BOGL, KW ;
NUSSE, M .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1992, 62 (06) :695-709
[18]   MULTIPARAMETRIC FLOW CYTOMETRIC ANALYSIS OF RADIATION-INDUCED MICRONUCLEI IN MAMMALIAN-CELL CULTURES [J].
SCHREIBER, GA ;
BEISKER, W ;
BAUCHINGER, M ;
NUSSE, M .
CYTOMETRY, 1992, 13 (01) :90-102
[19]   A NEW SUNLIGHT SIMULATOR FOR ECOLOGICAL RESEARCH ON PLANTS [J].
SECKMEYER, G ;
PAYER, HD .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1993, 21 (2-3) :175-181
[20]   THE PRESENT STATE OF THE AUTOMATED MICRONUCLEUS TEST FOR LYMPHOCYTES [J].
TATES, AD ;
VANWELIE, MT ;
PLOEM, JS .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1990, 58 (05) :813-825